Maintenance; Shut-Off Valve, Cold Water Inlet; Safety Valve; Non-Return Valve - Stiebel Eltron KV 30 Utilisation Et Installation

Masquer les pouces Voir aussi pour KV 30:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
INSTALLATION

Maintenance

9.
Maintenance
9.1

Shut-off valve, cold water inlet

For maintenance work on the following installation, you can shut
off the cold water inlet on the safety assembly.
Note
Note that the shut-off valve closes anti-clockwise.
The shut-off valve is unsuitable for setting the flow rate.
4
1 Shut-off valve, cold water inlet open
2 Pressure gauge connection
3 Shut-off valve, cold water inlet closed
4 Locking clip
14
| KV 30 | KV 307 | KV 40
9.2
Checking the safety valve
f For safety reasons, check the safety valve twice a year.
f
f Remove hot water until the heater of the DHW cylinder
f
switches on.
f Turn the bleed cap 2 to 3 times anti-clockwise.
f
During the heat-up process, expansion water will drip from the
1
safety valve into the tundish.
f Check the function of the non-return valve if no water drips
f
during heat-up.
2
No water must drip out after heat-up has been completed.
f Should water nevertheless drip after heat-up, clean the safe-
f
ty valve and check the water inlet pressure.
f KV 30 | KV 307: If necessary, install a pressure reducing valve.
f
KV 40: Check the function of the pressure reducing valve. If
necessary, clean or replace the pressure reducing valve.
Removing / cleaning the safety valve
3
f Isolate the DHW cylinder from the power supply.
f
f Rotate the shut-off valve 90° anti-clockwise to close the cold
f
water inlet.
f Open the tap to drain the DHW cylinder.
f
f Remove the safety valve with drip facility by removing the
f
locking clip.
f Clean the seat and gasket of the safety valve.
f
f Reinstall the safety valve with the locking clip.
f
f Check the safety valve.
f
9.3
Checking the non-return valve
f Check the non-return valve annually.
f
f Remove hot water until the heater of the DHW cylinder
f
switches on.
f Rotate the shut-off valve 90° anti-clockwise to close the cold
f
water inlet.
f Remove the pressure gauge screw.
f
No water must be expelled.
f If water drips, clean or replace the non-return valve.
f
f If cold water drips, open the shut-off valve clockwise in order
f
to flush out any dirt. Then close the shut-off valve anti-clock-
wise. If water continues to drip, check the gasket and seat in
the valve block. Replace the valve block if required.
9.4
f Replace the valve block if the shut-off valve proves to be
f
faulty.

Safety valve

Note
The safety valve cannot be repaired.
f In the case of faulty operation, replace the complete
f
safety valve.

Non-return valve

Shut-off valve

www.stiebel-eltron.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Kv 307Kv 40

Table des Matières