Product Description; Approvals And Markings; Function - DOLD SAFEMASTER STS RX10B01M/K Traduction De La Notice Originale

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety Technique
SAFEMASTER STS/K
Safety Switch- And Key Interlock System
Basic Unit RX10B01M/K and RX10K01M/K
RX10B01M/K
RX10B01M/K: Display in deactivated state:
1. key removed; actuator and 2. key inserted
RX10K01M/K: Display in deactivated state:
1. key inserted; actuator and 2. key removed

Product Description

Mechanical solenoid lockings for separating guards with forced key entry
and optional key removal as well as electrical monitoring function. To
secure separating guards such as safety gates and hoods in machine and
plant engineering.
All technical data in this list relate to the state at the moment of edition. We reserve the right for
technical improvements and changes at any time.
RX10K01M/K
STS/K-System Benefits
• EU-Test certificate according to the directive 2006/42/EG, annex IX
• For safety applications up to PLe / Cat. 4 acc. to DIN EN ISO 13849-1
• Modular and expandable system
• Rugged composite version of stainless steel and FRP design
• Wireless mechanical safeguarding
• Combines the benefits of safety switch, solenoid locking and
key transfer in a single system
• Easy installation through comprehensive accessories
• Protection against lock-in
• Coding level low, medium, high according to DIN EN ISO 14119:2014-03
Features
The unit is particularly suitable for applications with:
• Full body access (lock-in danger)
• Optional key removal
• Several secured entries
• Rugged ambient conditions
• This unit is also available in stainless steel

Approvals and Markings

Function

RX10B01M/K: Mechanical guard locking with monitoring of the first
or second key
After the first key has been inserted, the actuator and then the second
key can be removed.
With the variant RX10B01M/K, the contacts switch when the first key is
inserted, while with the variant RX10K01M/K the contacts switch when
the second key is removed.
Both versions are available with actuators of coding level low and medium
according to EN ISO14119:2013. The coding level medium can be retrofitted.
The second key can be used as part of a key transfer system or as a
personal key, i.e. as protection against confinement and unexpected restart.
Multiple keys make it possible to operate several units in the system or to
protect several people. The RX10B01M/K and RX10K01M/K units can be
expanded with additional key modules both below and above the actuator
module. By using personal keys, an escape release (ISO TS19837:2017)
can normally be dispensed with.
Both variants can optionally be equipped with padlock modules.
These units can be connected to the SAFEMASTER STS option module,
which includes command functions and is designed for wiring cross
sections up to 1.5 mm
2
.
19