Design and Operation
Attention!
Hazards must be ruled out before a key can be entered and
!
the movable part of the guard can then be opened!
The STS/K solenoid locking unit is to be integrated into a system and
connected with a control unit so that the hazardous machine can run only
when the guard is locked and closed.
After entering a first key into key module 10/K the actuator can be removed
from actuator module B/K and the access can be opened.
The key is blocked after removing the actuator. Only after the access is
locked and the actuator was returned to its starting position can the first
key be removed again and the solenoid locking is activated.
Mechanical guard locks are in the system in connection with additional
STS/K units and SAFEMASTER products. The key to be entered may
originate from these units (e.g. release through upstream solenoid locking
ZRH01BM/K in connection with a speed monitor UH 5947 or standstill monitor
LH 5946).
20
SAFEMASTER STS/K-M10BM/K, MK01M/K / 17.06.20 en / 245A