FIGURE 3 - PARTS DESCRIPTION AND PCBA TERMINALS
4
8
8
2
1
+
A
B
5
1
18
All manuals and user guides at all-guides.com
6
5
7
3
- M1 M2 +P
FIGURE 4 - TRANSPARENT COVER AND LEXAN
6
4.4
4
4.1
4.3
3
4.2
ESC
Connection Clamps
1
+ A B - : Connection clamps on KSI-BUS
for devices. All the devices have to be
connected in parallel, it is necessary to
connect each clamp with an equally named
one (clamp + is protected by a self-restoring
thermal fuse of 1.5 A)
M1 M2: Programmable clamps I/O
+P: Supply clamp for external devices (max
1,5A)
gemino e lares devices fast-connection cable
2
terminal
Anti-tear
3
Switch
Micro-controllor
5
Reserved
7
terminal
Alphanumeric keypad with 1 a 9, * and # keys
1
ESC key
2
ENTER key
3
Scroll, also including:
4
4.1. Left arrow
4.2. Down arrow
4.3. Right arrow
4.4. Up arrow
2
Display
5
RFID/NFC Area
6
ergo
Anti-tear
4
Switch
Microphone
6
Loudspeakers contact
8