Table Des Matières; Pre-Installation Requirements; Electrical Requirement; Grounding Requirements - Frigidaire FTF530FS Notice D'installation

Masquer les pouces Voir aussi pour FTF530FS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CONTENTS
SUBJECT
Pre-Installation Requirements.................................................2
Electrical Requirement..........................................2
Grounding Requirement........................................2
Water Supply Requirements..........................................2
Drain Requirements................................................2
Location Of Your Washer...........................................2
Unpacking......................................................2-3
Rough-In Dimensions.............................................3
Installation.......................................................4
Replacement Parts...............................................4
Français...........................................................5-8

PRE-INSTALLATION REQUIREMENTS

Tools Required for Installation:
1. 1/4 in. nut driver
2. 3/8 in. socket with ratchet.
3. 3/8 in. open end wrench.
4. 7/16 in. socket with ratchet.
5. 9/16 in. open end wrench.
6. Channel-lock adjustable pliers.
7. Carpenter's level.
ELECTRICAL REQUIREMENTS
CIRCUIT - Individual, properly polarized and grounded 15 amp.
branch circuit fused with 15 amp. time delay fuse or circuit breaker.
POWER SUPPLY - 2 wire, with ground, 120 volt, single phase, 60
Hz, Alternating Current. NOTE: The use of this washer with power
created by gas powered generators, solar powered generators, wind
powered generators or any other generator other than the local
utility company is not recommended.
OUTLET RECEPTACLE - Properly grounded 3-prong receptacle to
be located so the power supply cord is accessible when the washer is
in an installed position. NOTE: GFI (Ground Fault Interrupter)
receptacle is not required.

GROUNDING REQUIREMENTS

Improper connection of the equipment grounding
conductor can result in a risk of electrical shock. Check with a licensed
electrician if you are in doubt as to whether the appliance is properly
grounded.
1.
The washer MUST be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electrical shock by
a path of least resistance for electrical current.
2.
Since your washer is equipped with a power supply cord having
an equipment-grounding conductor and a grounding plug, the
plug MUST be plugged into an appropriate, copper wired
receptacle that is properly installed and grounded in accordance
with all local codes and ordinances or in the absence of local
codes, with the National Electrical Codes, ANSI/NFPA 70 (latest
edition). If in doubt, call a licensed electrician. DO NOT cut off
or alter the grounding prong on the power supply cord. In
situations where a two-slot receptacle is present, it is the owner's
responsibility to have a licensed electrician replace it with a
properly grounded three prong grounding type receptacle.
All manuals and user guides at all-guides.com
PAGE
2

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets MUST be installed within 42 inches (107
cm) of your washer's water inlet. The faucets MUST be 3/4 inch (1.9
cm) garden hose type so inlet hoses can be connected. Water pressure
MUST be between 10 and 120 pounds per square inch (maximum
unbalance pressure, hot vs. cold, 10 psi.) Your water department can
advise you of your water pressure.

DRAIN REQUIREMENTS

1.
Drain capable of eliminating 17 gals (64.3 L) per minute.
2.
A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.
3.
The standpipe height above the floor should be:
Minimum height:
Maximum height:
NOTE:
Drain hose attached to the washer can reach a 58 in. (147 cm)
high standpipe. For higher standpipe use hose P/N 131461201,
available from an authorized parts distributor. If drain is less
than 24 in. (61 cm), install a siphon break kit, available at your
local hardware store.

LOCATION OF YOUR WASHER

DO NOT INSTALL YOUR WASHER:
1. In an area exposed to dripping water or outside weather
conditions. The ambient temperature should never be below 60
degrees F (15.6 degrees C) for proper washer operation.
2. In an area where it will come in contact with curtains or drapes.
3. In an area (garage or garage-type building) where gasoline of
other flammables are kept or stored (including automobiles).
4. On carpet. Floor MUST be solid with a maximum slope of 1/2 in.
per foot (1.27 cm per 30.5 cm). To ensure vibration or movement
does not occur, reinforcement of the floor may be necessary.
IMPORTANT
MINIMUM INSTALLATION CLEARANCES
When installed in alcove or closet:
Sides, Rear = 0 in. (0 cm)
Top = 0 in. (0 cm) Front Console Model
Top = 15 in. (38.1 cm) Rear Console Model
When installed in closet: Front = 1 in. (2.54 cm)
Closet door ventilation required:
2 louvered openings each 60 in
and bottom of door.

UNPACKING

1. Cut the shipping carton along the dotted line along the base of
the unit.
2. While in the carton carefully lay the washer on its back side.
3. Remove the styrofoam base.
4. Carefully return the washer to an upright position and remove
the carton.
24 in. (61 cm)
96 in. (244 cm)
2
(387 cm
2
), 3 in. (7.6 cm) from top
Max.
Max.
Max.
Max.
Max.

Publicité

Table des Matières
loading

Table des Matières