Setting the maximum temperature
Factory setting: 38 °C
30°C
38°C
50°C
» Using a screwdriver, set the potentiometer to the
maximum required temperature.
» Fit the appliance cover.
All manuals and user guides at all-guides.com
Installation - for contractors
Limiting the flow rate
Factory setting: Maximum flow rate
» Using the adjusting screw, set the maximum required
flow rate:
◦ Lowest flow rate = wind the screw in as far as it will
go.
◦ Highest flow rate = wind the screw out as far as it will
go.
» Fit the appliance cover.