Online Support
http://www.bosch-indego.com
Problem
Possible Cause
The LED on the dock-
The perimeter wire is interrupted, too long
ing station flashes
or too short. Wire not connected and
mower not in the docking station.
Excessive vibrations/
Blade bolt loose
noise
Cutting blade damaged/bent
Mower not docking
Perimeter wire not properly layed out
reliably
around docking station
Perimeter wire close to a source of interfer-
ence
Mower fails to operate Isolator switch not turned on
Possible clogging
Battery not fully charged
Grass too long
Battery too hot/cold
Mower standing on
Problems whilst running
lawn with the display
switched off
Mower does not
Battery too hot/cold
charge
Docking station not switched on
Charging pins corroded
Bosch Power Tools
All manuals and user guides at all-guides.com
Corrective Action
Check that the perimeter wire is not interrupted and is
between 20 and 250 meters in length. Then switch
power supply off and then on again.
Follow instructions in Installation Guide on installing the
mower.
Tighten blade bolt to torque of 2.5 Nm.
Replace cutting blade (see figure K).
Follow instructions in Installation Guide on layout of peri-
meter wire.
Remove any excess (e.g. coiled up) perimeter wire
around the docking station.
Change perimeter wire ID in the menu.
Remove mower out of docking station, turn isolator
switch on and place mower back into docking station (en-
sure docking station is on – LED lights up green).
Always turn isolator switch off first, then check under-
neath the mower and clear out as necessary (always wear
protective gloves).
Place mower in the docking station to allow to charge.
Docking station must be powered on.
Mow lawn with conventional lawnmower to its lowest
height-of-cut setting before using the mower.
The mower operates when the battery internal battery
temperature is between 5 °C – 45 °C. Allow mower to
cool down/warm up. If the error occurs frequently, the
docking station should be positioned in the shade.
Press confirm button for screen to light up, or place
mower in docking station.
The mower operates when the battery internal battery
temperature is between 5 °C – 45 °C. Allow mower to
cool down/warm up. If the error occurs frequently, the
docking station should be positioned in the shade.
Switch on power supply to docking station. If docking
station does not start, contact your Bosch Service
Centre.
Clean the charging pins.
English | 27
F 016 L81 848 | (01.10.2018)