Propane Cylinder Installation: Pull out the tank drawer (do not disengage slides). Set cylinder inside tank ring.
Natural Gas Hook-Up: These connections must be made by a licensed gas installer. This natural gas grill is sup-
plied with a 12 foot. (3.6 meter) supply hose and quick disconnect designed for natural gas and certified for
outdoor use. The gas grill is designed to operate at an inlet pressure of 4.5 in. water column. Piping and valves
upstream of the quick disconnect are not supplied. The installation must comply with CAN B149.1 Natural Gas
and Propane installation code in Canada, or to the National Fuel Gas Code, ANSI Z223.1 in the United States.
The gas supply pipe must be sufficiently sized to supply the BTU/h specified on the rating plate, based on the
length of the piping run.
The quick disconnect must not be installed in an upward direction and a readily accessible manual shut-off
valve must be installed upstream of, and as close to, the quick disconnect as is feasible. The flared end of the
hose must be connected to the unit as illustrated in the Natural Gas Hose Attachment diagram. Leak test all
joints prior to using the gas grill.
WARNING!
For your safety, conversion kits are not available. It is manufactured to exact specifica-
tions. Any attempt to convert your grill will void your warranty. Failure to follow these instructions could
result in property damage, personal injury or death.
WARNING!
A leak test must be performed annually and each time a cylinder is hooked up or if a part
of the gas system is replaced.
Leak Testing Instructions
WARNING!
A leak test must be performed annually and each time a cylinder is hooked up or if a part
of the gas system is replaced.
WARNING!
Never use an open flame to check for gas leaks. Be certain no sparks or open flames are
in the area while you check for leaks. Sparks or open flames will result in a fire or explosion, damage to
property, serious bodily injury, or death.
Leak testing: This must be done before initial use, annually, and whenever any gas components are replaced
or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak Testing
Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator, hose,
manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one recommend-
ed by the Napoleon Customer Care department and have the grill inspected by a certified gas installer.
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill inspected
by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.
5
www.napoleongrills.com