Maytag MDE18PD Instructions D'installation page 14

Sèche-linge à gaz ou électrique à usage commercial
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DRYER VENTING REQUIREMENTS
Vent Hoods
102 mm (4") Diameter Exhaust Hoods
Box Hood
Louvered Hood
Vent System Length
Maximum Vent Length/Vent Connection
Maximum length of vent system depends upon the type of vent
used, number of elbows, and type of exhaust hood.
Vent System Chart (Rigid Metal Vent)
No. of 90˚ Turns
Louvered Hood
0
39.6 m (130 ft.)
1
38.1 m (125 ft.)
2
35.1 m (115 ft)
3
32.3 m (106 ft.)
4
29.9 m (98 ft.)
For vent systems not covered by the vent specification chart,
see your parts distributor.
Provision must be made for enough air for combustion and
ventilation. (Check governing codes and ordinances.) See
"Recessed Area and Closet Installation Instructions" in the
"Location Requirements" section.
A 102 mm (4") outlet hood is preferred. However, a 64 mm (2
outlet exhaust hood may be used. A 64 mm (2
greater back pressure than other hood types. For permanent
installation, a stationary vent system is required.
Connect Vent
1. If connecting to existing vent, make sure the vent is clean.
2. Using a 102 mm (4") clamp, connect vent to exhaust outlet
in dryer.
NOTE: Do not remove vent collar.
14
All manuals and user guides at all-guides.com
Angled Hood
Box and
Angled Hood
39.3 m (129 ft.)
36.3 m (119 ft.)
33.2 m (109 ft.)
30.5 m (100 ft.)
28.0 m (92 ft.)
1
") outlet creates
2
Vent Collar
Exhaust hood must be at least 305 mm (12") from the ground or
any object that may be in the path of the exhaust (such as flowers,
rocks, bushes, or snow).
3. Tighten hose clamp with Phillips screwdriver.
4. Make sure the vent is secured to exhaust hood with
a 102 mm (4") clamp.
")
1
2
5. Move dryer into final position. Do not crush or kink vent.
Make sure dryer is level.
305 mm min.
12" min.
(305 mm)
(12")

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mdg18pd

Table des Matières