Fastening the Drill Stand
Note: Fasten the drill stand free from play to prevent
jamming of the core bit and the tearing out of seg-
ments.
Depending on the type and nature of the structural
material, fasten the drill stand where the bore hole is
intended using an anchor, with vacuum or with the
quick-clamping column.
Positioning the Drill Stand before Fastening
12
GDB 2500 WE
GDB 1600 WE/DE
Fold out the drill-hole center indicator 12. When work-
ing with the GDB 2500 WE, bring the tip of the drill-
hole center indicator into alignment with the marked
center of the intended bore hole. When working with
the GDB 1600 WE/DE, the inner edge of the drill-hole
center indicator 12 is the reference point.
For offset drilling, move the drill stand away from the
bore hole center by the value m:
Drilling angle
m*
m**
15°
30°
45°
m* : GDB 2500 WE
m**: GDB 1600 WE/DE
Fasten the drill stand using an anchor, with vacuum or
with the quick-clamping column. Then fold in the drill-
hole center indicator 12.
8 | English
All manuals and user guides at all-guides.com
Fastening with Anchor (see figure C)
For fastening of the drill stand to brickwork or concrete
with anchor (accessory), drill a separate anchor hole.
Clearance from anchor hole–center of the intended
bore hole
GDB 2500 WE
GDB 1600 WE/DE
For offset bore drilling, increase the distance between
the anchor hole and the center of the intended bore
hole by the value m (see "Positioning the Drill Stand
before Fastening").
The following dimensions apply for the anchor hole:
Brickwork
Concrete
12
Insert a concrete hammer-drive anchor or a brickwork
anchor 24. Screw the quick-clamping spindle 25 into
the anchor.
Position the drill stand, attach a washer, and then
screw together with the wing nut 26. After leveling (see
"Leveling"), tighten the wing nut using an open-end
wrench, size 27 mm.
Fastening with Vacuum
For fastening the drill stand with vacuum, a Bosch vac-
uum set and a Bosch vacuum pump (both accessories)
are required.
For fastening with vacuum, the surface must be smooth
and level. Application on plaster/stucco or brickwork is
m
not possible.
For connection of the Bosch vacuum set and vacuum
0 mm
pump, read and follow the respective operating instruc-
tions.
30 mm
80 mm
Fastening with a Quick-clamping Column
160 mm
(see figure D and E)
With use of a Bosch quick-clamping column (acces-
sory), the drill stand can be fastened between ceiling
and floor or between two walls. The clamping range is
between 1.7 m and 3 m.
Position one end of the quick-clamping column onto
the base plate of the drill stand. The mounting surface
for the other end of the quick-clamping column against
the wall must have sufficient stability and be secure
against slipping.
For fastening of the quick-clamping column, read and
follow the respective operating instructions.
optimal
330 mm
270 mm
Diameter
20 mm
15 mm
The safety and operating instructions for the
vacuum pump and vacuum set are to be strict-
ly observed!
possible
310–380 mm
250–320 mm
Depth
85 mm
50 mm
1 609 929 J56 • 9.1.07