6. LIGHTING AND REGULATING COMBUSTION
The Insert Fireplace must be closed at all
times during combustion to prev ent smoke
from leaking out. Only open to reload.
Follow
the
instructions
combustion:
- MOVING the regulation lever from right to left, a
greater air flow is provided for combustion.
(See Figure).
- T O ASSIST lighting, it is recommended to move
the burn regulation lever fully to the left.
It is essential to provide an abundant load of fuel
when lighting. T he following loads will depend on
the heat requirement desired.
It is adv isable to leave the door partially open to
avoid condensation and keep the glass clean for
some minutes after lighting the fire.
Once the fireplace has got going at its normal
level and the chimney has heated up, regulate
combustion by means of the regulation lever.
When the inflow of air is fully closed, combustion
will be slow; when the inflow of air is open,
combustion will be more intense.
In order to make the most of your device,
place the combustion regulation lever in the
central position.
When the device is to be used in the same room
as other heating devices that require air for
combustion
purposes,
additional inflow of air from outside to facilitate
combustion in all the said devices.
T he use of one or more heating devices in the
same room reduces the level of available oxygen,
affecting the combustion of the fireplace and
reducing the draw of the chimney.
T he top part of the front glass pane does not
include any sealing in order to allow air to enter to
Clean the glass during combustion this inflow of
air is constant and cannot be regulated.
All manuals and user guides at all-guides.com
below
to
regulate
we
recommend
an
The said inflow of air also allows a
secondary combustion process at the top part
of the dev ice.
Moving the regulation lever as described
above provides a greater inflow of air for
combustion. T his inflow of air enters through the
lower part of the log holder which, in turn, divides
it into two independent flows: one to the lower part
of the glass pane and the other towards the centre
of the cast iron base. (Each time logs are added,
check that the said air inflow areas are free of
ash. If they are not, clean them in order to
facilitate a correct combustion process).
ATTENTION! When w orking, the metal parts
of the fireplace may reach high temperatures.
Protect your hands w ith a fireproof glov e
w hen touching the said parts.
If you should detect any overheating of the
fireplace caused by:
Fan breakdown.
Faulty thermostat.
You should shut down the device in order to avoid
damaging
cast
iron
recommendations:
• Do not add any more fuel
• Open the door slightly to let more air in; this
will cause the flames to grow and consume the
fuel more quickly but will also cool the chimney
and reduce draw, cooling the device
Your Insert Fireplace has not been designed to
operate
with
an intermittent
system.
parts.
Follow
these
combustion