Installa on of ven ng (indoor models only) 
Install the correct ven ng for your model according to the ven ng manufacturer's instruc ons and the 
guidelines below.  Refer to the manufacturer's technical literature for specific part numbers and instruc ons.   
Manufacturer 
Listed and Tested Vent Products 
Ubbink 
Rolux Condensing Vent System  
InnoFlue Vent System (single wall 
Centrotherm 
Heat‐Fab 
Metal‐Fab 
Corr/Guard Vent/Air Intake System 
Manufacturer 
Product 
Ubbink 
Centrotherm 
InnoFlue  
Heat‐Fab 
Saf‐T Vent  
Metal‐Fab 
Corr/Guard 
  Ven ng Guidelines   
DO NOT 
Do not use PVC, CPVC, ABS or galvanized material 
to vent this appliance. 
Do not combine vent components from different 
manufacturers. 
Vent diameter must not be reduced. 
Do not connect the ven ng system with an 
exis ng vent or chimney. 
Do not common vent with the vent pipe of any 
other manufacturer's water heater or appliance.  
Rinnai water heaters can only be common vented 
using a Rinnai cer fied common vent system. 
MUST DO 
This water heater is a direct vent water heater and 
therefore is cer fied and listed with the vent 
system.  You must use vent components that are 
cer fied and listed with the water heater model. 
The vent system must vent directly to the outside 
of the building and use outside air for combus on. 
Avoid dips or sags in horizontal vent runs by 
installing supports per the vent manufacturer's 
instruc ons. 
12 
SW, 3 inch diameter) 
Saf‐T Vent SC system 
Ver cal Termina on 
Rolux  
Saf‐T Vent CI Plus Wall Termina on 
 
 
 
Telephone 
800‐621‐9419 
877‐434‐3432 
800‐772‐0739 
800‐835‐2830 
184162PP 
ICRT3539 
3CGRVDK 
 
 
 
 
 
Support horizontal vent runs every four feet and 
all ver cal vent runs every six feet or in 
accordance with local codes. 
Ven ng should be as direct as possible with a 
minimum number of pipe fi ngs. 
Vent connec ons must be firmly pressed together 
so that the gaskets form an air  ght seal. 
The vent piece connected to the water heater 
must be secured with one self‐tapping screw. 
INFORMATION 
Refer to the instruc ons of the vent system 
manufacturer for component assembly 
instruc ons. 
If the vent system is to be enclosed, it is suggested 
that the design of the enclosure shall permit 
inspec on of the vent system.  The design of such 
enclosure shall be deemed acceptable by the 
installer or the local inspector. 
NOTICE 
If it becomes necessary to access an enclosed vent 
system for service or repairs, Rinnai is not responsible 
for any costs or difficul es in accessing the vent 
system.  The warranty does not cover obtaining 
access to a vent system in an enclosed environment. 
KB Series Manual 
Fax 
678‐829‐1666 
info@centrotherm.us.com 
518‐618‐3166 
www.centrotherm.us.com 
custsvc@heat‐fab.com, 
413‐863‐4803 
www.hea ab.com 
info@mtlfab.com, 
316‐943‐2717 
www.metal‐fabinc.com 
Horizontal Termina on 
223176PP, 223177PP 
ISELL0387UV 
Saf‐T Vent CI Plus Rain Cap 
3CGRVT 
Contact 
www.rinnai.us 