DESCRIPTION
Type 6120 is a device that can be used in
those cases in which you want to make an
Elvox Two-wIRE door entry or video door
entry system function remote-controlled (e.g.
opening the lock or outside door call). It is in-
stalled along the bus line of an eLvox Two-
wIRE system.
Module type 6120 receives the command
from two N/o push-buttons (connected to
terminals IN1 and IN2 shown in Fig. 1) and
when closing, they send the ID code as-
signed to them.
up to eight type 6120 devices with different ID
codes can be installed in the same system, or
more than eight with ID = 0. The ID code is
indispensable for the programming phases,
so it is necessary to identify each device with
its own ID during this step. when there are
more than eight type 6120 devices, assign
ID0 to the type 6120 devices not to be pro-
grammed, and ID1 to ID7 for the devices to
be programmed.
If used in a monitor or mixed system, the ABC
connector lets you make the termination of
the bus for adapting the video signal using
the special jumper.
The bus connects to the B1 and B2 terminals.
DIMENSIONS: 48x70x19 mm
Fig. 1
D3
DESCRIPTION OF TERMINALS AND
COMPONENTS INVOLVED (fig. 1)
B1,B2,) Pair of terminals for BuS line
IN1)
Pair of terminals for connecting the
1st push-button with the N/o con-
tact.
IN2)
Pair of terminals for connecting the
2nd push-button with the N/o con-
tact.
1 2 3)
Dip-switch for setting the device ID
code.
D3)
LeD programming status signalling.
EN
All manuals and user guides at all-guides.com
ABC)
Jumpers for BuS termination.
)
Push-button for programming
(push-button function association).
OPERATION
Attention: in order for the push-button
module to work correctly in 100% of the
cases, all of the devices (door entry sys-
tems, video door entry systems, entrance
panels) must be updated to software ver-
sion 4 or higher. Otherwise, some func-
tions could be limited.
The programming is based on the combined
use of a push-button inside the printed circuit
indicated by the symbol
two external push-buttons (to be connected to
the IN1 and IN2 terminals).
when starting, the lED flashes for 2 seconds
with 400-ms cycle as a check that the device
has been programmed with the correct Firm-
ware, then it turns off. The lED flashes for
100 ms also with every data packet travelling
through the bus to which it is connected.
ID
Correspondence between the position of the
dip switch 123 and the ID used in the eLvox
Two-wIRE system is shown in the follow-
ing table. oFF means that the dip-switch is
moved downward, towards the exterior of the
container.
DIP1 DIP2 DIP3
oFF
oFF
oN
oFF
oFF
oN
oN
oN
oFF
oFF
oN
oFF
oFF
oN
oN
oN
PROGRAMMING
To program a push-button not using the
programmer or similar device, follow these
directions:
• Keep the push-button pressed
• Press the push-button to be programmed
(push-button connected to IN1 or IN2)
• The raised hook devices emit a rising three-
tone scale in the load speaker
• The D3 lED starts to flash with a 200-ms
cycle if the push-button connected to IN1
is pressed, and with a 600-ms cycle if the
push-button connected to IN2 is pressed
• Release all of the push-buttons
• From this very moment you have 30 sec-
onds to complete programming
- To return to the default setting (i.e. no
association), press the same push-button
again. The lED flashes for 2 seconds with
a 100-ms cycle
- To associate a lock opening with the
push-button, make a call from the entry
, a LeD (D3) and
ID
oFF
ID0
oFF
ID1
oFF
ID2
oFF
ID3
oN
ID4
oN
ID5
oN
ID6
oN
ID7
panel involved to any extension, even one
that does not exist
- To use as door call function with one
or more (video) door entry systems with-
out requiring direct connections between
push-buttons and devices, press any
push-button on the device Head-group,
which executes the lock command function
or call to the switchboard, function F1 or F2
or command to an actuator (e.g. stairway
light).
• when the command is received, the lED
stays on steady for 2 seconds, then turns
off.
• To cancel the entire programming proce-
dure, press
again. The lED flashes
for 2 seconds with a 100-ms cycle.
PROGRAMMING WITH PROGRAMMER
It is possible to configure the push-buttons
both with the programmer type 950C and with
the SaveProg software for PC. with these in-
struments, the two push-buttons can be pro-
grammed even for operating an actuator or
for controlling outputs F1 or F2 of a specific
panel (if equipped with one). Note that for the
first four push-button IDs, F1 and F2 are of
panels 1..8. For the second set of four IDs,
they are of panels 9..15.
Please note that the first push-button corre-
sponds to P5, the second to P6.
INSTALLATION RULES
Installation should be carried out observing
current installation regulations for electrical
systems in the country where the products
are installed.
CONFORMITY
eMC directive
Standards eN 61000-6-1 and eN 61000-
6-3.
INFORMATION FOR USERS UN-
DER DIRECTIVE 2002/96 (WEEE)
In order to avoid damage to the envi-
ronment and human health as well as
any administrative sanctions, any appliance
marked with this symbol must be disposed
of separately from municipal waste, that is it
must be reconsigned to the dealer upon pur-
chase of a new one. Appliances marked with
the crossed out wheelie bin symbol must be
collected in accordance with the instructions
issued by the local authorities responsible for
waste disposal.