Provide adequate support for the suction and delivery pipes so that they do not weight
down on the pump. Do not make the couplings between the pipes too tight. Suction pipe
diameter > = diameter of the electropump opening.
-
Fit one gate valve in the suction pipe and one in the delivery pipe to isolate the pump.
-
Fill the pump, slowly and completely opening the gate valve in the suction pipe, and
keeping the gate valve on delivery open to let the air out.
6.4

INSTALLATION ABOVE WATER LEVEL

-
If there are several suction pipes, arrange the pipes and the manifold below water level
and reach the pump with only one vertical pipe. Reduction of priming time with a shorter
suction pipe.
-
Fill the pump with water up to the level of the suction mouth, through the opening of the
filling cap.