9. Operation
b) Manual Operation
Operation at the device
• Push the button FUNC until the display shows out.
• Set the desired amount of fog with the arrow buttons and confirm with the button ENTER.
F001
Minimum fog amount
F100
Maximum fog amount
Manual operation with remote control
• Press the green MANUAL button on the remote control.
• The device emits fog as long as you keep this button pressed.
Permanent operation with remote control
• Press the red CONT button on the remote control.
• The device emits fog permanently and the red indicator LED is lit.
• Set the desired fog quantity using the VOLUME controller.
• To deactivate permanent operation, push the red CONT button on the remote control again.
Interval operation with remote control
• Press the yellow TIMER button on the remote control.
• The device now emits fog time-controlled and the yellow indicator LED is lit.
• Set the desired interval time using the INTERVAL controller.
• The device emits fog for the set time and then pauses for as long as the set time as well. Then the described interval
starts over.
• To deactivate interval operation, push the yellow TIMER button on the remote control again.
c) Operation via a DMX Controller
Each DMX device in a DMX chain requires an assigned DMX channel to be clearly targeted by the controller.
• Push the button FUNC until Addr is displayed and push the button ENTER.
• Select the desired start address A001-A512 with the arrow buttons.
• Press the ENTER button to confirm your selection.
• The set DMX channel can be used to set the fog volume now.
DMX value 000 > no fog output
DMX value 255 > maximum fog output