Device Information - Dimplex LIKI 14TE Instructions D'installation Et D'utilisation

Pompe à chaleur air-eau pour installation intérieure
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

11

11 Device information

1
Type and order code
2
Design
2.1
Model
2.2
Degree of protection according to EN 60 529 for compact devices and heating
2.3
Installation location
3
Performance data
3.1
Operating temperature limits:
Heating water flow
Air
3.2
Temperature spread of heating waterat A7 / W35
3.3
Heat output / COP
3.4
Sound power level device / outdoors
3.5
Sound pressure level at a distance of 1m/
Indoors, in heating operation at flow temperature 35°C
3.6
recommended heating water flow rate
2
minimum heating water flow
3.7
Free compression of heat circulating pump (max. level)
3.8
Air flow with an external static pressure differential of
3.9
Refrigerant; total filling weight
3.10 Oil type / Volume
3.11 Output of electric heating element (2nd heat generator)
4
Dimensions, connections and weight
4.1
Device dimensions
4.2
Device connections to heating system
4.3
Air duct inlet and outlet (min. internal dimensions)
4.4
Weight of the transportable unit(s) incl. Packing
4.5
Buffer tank volume
4.6
Buffer tank pressure rating
4.7
Nominal volume expansion vessel
5
Electrical connection
5.1
Nominal voltage; fuse protection
(combined infeed HP and HG2)
5.2
Fuse protection for separate infeed: HP / HG2
5.3
Nominal power consumption
5.4
Starting current with soft starter
5.5
Nominal current A2 W35 / cosϕ
5.6
Max. power consumption of compressor protection,
thermostat controlled
6
Complies with the European safety regulations
7
Additional model features
7.1
Defrosting
Type of defrosting
Defrosting tray included
7.2
Heating water in device protected against icing
7.3
Performance levels
7.4
Regulator internal/external
1. This data indicates the size and capacity of the system according to EN 255 and EN 14511. For an analysis of the economic and energy efficiency of the system, other parameters,
in particular the defrosting capacity, the bivalence point and regulation, should also be taken into consideration. The specified values have the following meaning e.g. A2 / W35:
External temperature 2 °C and heating water flow temperature 35 °C.
2. The heat circulating pump is integrated.
3. The heat circulating pump and the heat pump controller must always be ready for operation.
E-10
All manuals and user guides at all-guides.com
°C / °C
°C
1
at A-7 / W35
kW / ---
1
at A-7 / W45
1
at A2 / W35
kW / ---
1
at A2 / W55
1
at A7 / W35
kW / ---
1
at A7 / W45
kW / ---
1
at A10 / W35
kW / ---
dB(A)
dB(A)
m³/h / Pa
Pa
m³/h / Pa
m³/h / Pa
type / kg
Type / l
kW
W x H x D cm
Inch
L x W cm
kg
l
bar
l
V / A
A
1
A2 W35
kW
A
A / ---
W
3
LIKI 14TE
Compact
IP 20
Indoors
Up to 65
-25 to +35
5
7,3 / 2,6
7,4 / 2,7
7,2 / 2,2
9,9 / 3,4
10,1 / 3,6
8,8 / 2,1
11,7 / 3,9
11,9 / 4,1
11,6 / 3,3
12,5 / 4,1
12,6 / 4,2
52 / 58
45
2,0 / 3100
1,0 / 800
50000
3500 / 0
3000 / 25
R417A / 4.8
Polyolester (POE) / 1.89
3,0 / 6,0
96 x 210 x 78
G 1 1/4" external
726 x 726 / 552 x 355
365
120
3
24
400 / 25
16 / 10
2,91
27
5,5 / 0,8
70
See CE declaration of conformity
Automatic
Reverse circulation
Yes (heated)
Yes
1
Internal
10
2,80