Sommaire des Matières pour Oneida Air Systems DUST GORILLA PRO XGK030105H-S35VP
Page 1
Oneida Air Systems, Inc. a été fondée en 1993 pour mettre le coût, les systèmes état -of-the-art de dépoussiérage et de manutention conduits efficace pour les ateliers de menuiserie. OAS conçoit et fabrique des systèmes de classe industri-...
Page 2
All manuals and user guides at all-guides.com System Start-Up Information Read the installation and maintenance instructions as well as the recommended safety practices in this manual. / Lisez les instructions d’installation et d’entretien ainsi que les pratiques de sécurité recommandées dans ce manuel. WARNING / AVERTISSEMENT Do not operate Fan / Blower unless Fan Housing is attached DANGER...
All manuals and user guides at all-guides.com System Contents / le contenu du système FPZ000018 BHX020005B SXI002108 BXI030118C / BXI050118C FCS183600HF SCX002109 Optional 35 & 55 Gal. Drum Kits - OEK550901 / OEK350901 STX002100 SEX550900 ACB120000 DHF090000 FPX000001 SES350000 SES550000 Optional Stand - STZ212300 Optional Wall...
Page 4
All manuals and user guides at all-guides.com System Contents / le contenu du système Suggested Tools: 9/16” Wrench Filter 9/16” Socket Wrench Grounding Wire 1/2” Wrench 1/2” Socket Wrench Tape Ruler Motor Cowling 8ft. Ladder Scissors On / Off Box AFB155175 - (7) Hook AFW180000 - (7)
Page 5
All manuals and user guides at all-guides.com Specifications System 1625 Max. CFM Performance Height w/ 35 Gallon Drum: 94” System Footprint w/ Ext. Cartridge: 36” x 48” Inlet Diameter: Welded 7” w/ Neutral Vane Dimensions Powder Coated Paint Finish Over Heavy Gauge Steel Seam-Welded Cyclone 35 Gal.
All manuals and user guides at all-guides.com Dimensions For Minimum Mounting Heights w/ 36” Filter & 35 / 55 Gal. Drums *Dimensions subject to slight variation in manufacturing. Attention: All metal ductwork should go inside of the inlet. All flexible hose ductwork should go on the outside of the inlet.
All manuals and user guides at all-guides.com Fan Housing Assembly Instructions / Assemblée Instructions Instructions for Attaching Motor Plate to Fan Housing / Make sure that the fan housing is oriented Instructions pour Fixation de la plaque du moteur au like this diagram before you attach clips logement Fan.
Page 8
All manuals and user guides at all-guides.com Assembly Instructions Do NOT use hook on motor to lift unit. With all assemblies, make sure rectangular air outlet is oriented on Fan/Blower housing as you are looking down as in Pg. 6 This is very important. / Avec toutes les assemblées, assurez-vous que la sortie d’air rectangulaire est orien- tée sur le logement Fan / ventilateur que vous êtes à...
Page 9
All manuals and user guides at all-guides.com Put gasket material around top rim of barrel, outside of the bolt holes, again making sure that there is no gap where the ends meet. Make sure that the housing’s outlet is oriented in the direction that fits your shop layout and the pre-installed nuts are on the underside of the top.
All manuals and user guides at all-guides.com Stand Assembly / Tenez Assemblée 35 Gal. Stand - STZ212300 Stand Kit Contents / Tenez-Contenu du kit 21” 21” 30” 30” Optional Stand Leg Extension for use with 55 Gal. Drum or Universal Drum Dolly STX212304 - 21-23 Inch Leg Extension 1.
Page 11
All manuals and user guides at all-guides.com Wall Bracket Assembly / Ensemble de console murale Optional 1. The collector will seem quieter if the outlet is aimed away from the area people tend to work. Slots in the brack- ets are .406” x 1.00”. Note: Bolts included to mount bracket to collector.
Page 12
All manuals and user guides at all-guides.com Filter Assembly / filtrer Assemblée Make sure your filter is in the proper position for your ductwork set up. See filter positions pg.18 for further External 39” Filter Assembly information. *Silencer Included / Silencieux Inclus Outlet - Fig.
Page 13
All manuals and user guides at all-guides.com 3. Attach Plenum to outlet using the included (7) 3/8 x 1” bolts with 2 wash- Filter Plate - Fig. 2 ers and a whiz nut, making sure the support hanger on the Plenum is at the 4 hole side is near dust bottom.
All manuals and user guides at all-guides.com Flex Hose Connection Cone to Drum / Tuyau Flex connexion Cone Drum If you are having trouble getting your drum Drum Grounding Wire out to empty it, you can cut down the flex / Tambour Fil de terre hose to give yourself more room.
All manuals and user guides at all-guides.com Directions for Cleaning External Filter / Itinéraire pour nettoyage filtre externe All steps should be done with a dust mask and eye protection. Proper filter cleaning should not be neglected. A dirty filter can affect dust collector operation and filter life./ Toutes les étapes doivent être faites avec un masque anti-poussière et des lunettes de protection.
All manuals and user guides at all-guides.com Filter Grounding Wire Figure 1 Attach the ring terminal on the braided ground wire from the motor to a bolt on the filter plate, under the nut. Then attach the alligator clip to the filter cage as shown in Fig.
All manuals and user guides at all-guides.com Fan Motor Maintenance / Moteur de ventilateur Entretien Per Baldor specifications, their 2 pole motors (3,600 rpm) are to be relubricated every 5,500 hours. / Par spécifica- tions Baldor, leurs deux moteurs de pôles (3600 rpm) doivent être graissés toutes les 5500 heures. Table 1 - Service Conditions / Conditions de service Ambient Temperature Type of Bearing / Type...
All manuals and user guides at all-guides.com Accessories Stand Leg Extension Part # Description Bolt Together Stand STZ212301 Leg Extension Kit STZ212300 - 35 Gal. Stand Adjustable extensions allow use of 55 gal. drum and Universal Drum Dolly on 35 and 55 gal.
All manuals and user guides at all-guides.com Possible Filter Positions - Not Possible Filter Positions - Fan housing and cyclone bolt holes are drilled at 45 degree increments. Some orientations are not possible. Please check your design. Filter hits inlet pipe. Inlet Inlet WALL BRACKET...
Page 20
All manuals and user guides at all-guides.com Poor Dust Pick-Up at Woodworking Machines Dust pauvres Pick-Up à Machines à bois Caused By: Causée Par: Une mauvaise rotation du moteur - Exécution arrière Improper motor rotation - Running backwards will réduira aspiration de 30% reduce suction by 30% Vérifiez la longueur des tronçons de conduits et diamètres de Check length of duct runs and duct diameters compared to...
All manuals and user guides at all-guides.com Fire Hazards / Risques D’incendie Read before installing and operating Lire avant d’installer et d’exploitation. Wood shaping and cutting processes generate wood Processus de mise en forme et la coupe de bois génèrent des copeaux de bois , les copeaux et la poussière .
Page 22
All manuals and user guides at all-guides.com The customer assumes the responsibility for contacting Le client assume la responsabilité de communiquer avec leur their insurance underwriter with regard to specific applica- souscripteur d’assurance à l’égard des exigences spécifiques à tion requirements of explosion venting or if additional fire l’application d’explosion ventilation ou si la protection incendie protection and safety equipment may be required.
Oneida Air Systems shall be tried in the State of New York, County of Onondaga. / Bons Oneida Air Systems ™ les produits fabriqués par Oneida Air Systems, pour une période de 1 an ou plus selon le produit , à l’acheteur original de la date d’achat , sauf indication contraire .
Oneida Air Systems se réserve le droit d’apporter des modifications aux produits et les prix à tout moment. En tant que producteur, Oneida Air Systems se réserve le droit de modifier la conception et les spécifications des produits à tout moment.
Page 25
All manuals and user guides at all-guides.com Optional Ductwork Infinite Adjustability Made in the USA Adjustable, Fast Installation Now you can make the infinite adjustments to fit any length requirement. The exclusive adjustability of our fittings makes Gorilla Duct™ the clamp- together duct that is infinitely adjustable.