Whirlpool KGRA806PSS Instructions Pour L'installation page 14

Autoportantes et encastrables de 30" (76,2 cm)
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

To Convert Standard Surface Burners
1. Remove burner cap.
2. Using a T20 TORX
®
screwdriver, remove the burner base.
3. Apply masking tape to the end of a 7 mm nut driver to help
hold the gas orifice spud in the nut driver while changing it.
Press nut driver down onto the gas orifice spud and remove
by turning it counterclockwise and lifting out. Set gas orifice
spud aside.
A
B
A. Igniter electrode
B. Gas tube opening
C. Burner cap
D. Burner base
4. Gas orifice spuds are stamped with a number, marked with
1 color dot, and have a groove in the hex area. Replace the
Natural gas orifice spud with the correct LP gas orifice spud.
A. Groove
Refer to the following chart for correct LP gas orifice spud
placement.
LP Gas Orifice Spud Chart for Standard Surface Burners
Burner Location
Burner Rating
Right front
5,000 Btu/h
Left front
13,000 Btu/h
Right rear
10,000 Btu/h
Left rear
5,000 Btu/h
5. Place Natural gas orifice spuds in plastic parts bag for future
use and keep with literature package.
6. Replace burner cap.
7. Repeat steps 1-6 for the remaining burners, except for the
three flame burner (on some models). See "To Convert Three
Flame Burners" section.
To Convert Three Flame Burner (on some models)
1. Remove burner cap.
2. Remove the burner head using a size T20 TORX
14
C
D
A
Color
Size
Red
0.70 mm
Green
1.10 mm
Blue
0.95 mm
Red
0.70 mm
®
screwdriver.
3. Remove the plate on the external gas orifice spud.
A. Burner caps
B. Burner heads
C. External gas orifice spud access plate
D. Internal gas orifice spud
IMPORTANT: The three flame burner has 2 gas orifice spuds.
Do not forget to change the external gas orifice spud located
under the plate.
B
C
A. Plate
B. External gas orifice spud
C. Internal gas orifice spud
4. Apply masking tape to the end of a 7 mm nut driver to help
hold the internal gas orifice spud in the nut driver while
changing it. Press nut driver down onto the internal gas
orifice spud and remove by turning it counterclockwise and
lifting out. Set internal gas orifice spud aside.
5. Use a 7 mm combination wrench to remove the external gas
orifice spud. Turn counterclockwise to remove. Set external
gas orifice spud aside.
6. Replace each Natural gas orifice spud with the correct LP gas
orifice spud. Refer to the following chart for correct LP gas
orifice spud placement.
LP Gas Orifice Spud Chart for Three Flame Burners
Burner Location
Burner Rating
Left front (external
11,800 Btu/h
three burner)
Left front (internal
threeburner)
7. Replace burner plate, head and cap.
8. Place Natural gas orifice spuds in plastic parts bag for future
use and keep with literature package.
A
B
C
D
A
Color
Brown
2,200 Btu/h
Orange
Size
1.00 mm
0.42 mm

Publicité

Table des Matières
loading

Table des Matières