OPERATION
• Flow is triggered when hand is put in front of the sensor.
• Voluntary shut-off when hand placed a second time in front of the sensor, or automatically after 1 minute of flow
(safety time flow).
FEATURES
• Never remove the non-return valves that are integrated in the water inlets (imperative).
• The nanny joint can be reversed in order to adapt to a water connection from above or below.
• This product is designed to withstand thermal and chemical shock in the framework of current regulations.
• Anti-bacterial proliferation duty flush: automatic flush for ~60 seconds every 24 hours after the last use.
Electrical supply:
• Battery-operated version: Two 3V Lithium batteries supplied. Please store at room temperature ≥ 5°C.
• Mains supply versions: 100-240V / 50-60 Hz class II SELV (separated from earth). The installation must
comply with local norms and regulations. If the supply cables is damaged it must be replaced by the installer.
The cables must be held in placed by a fixed installation (collar or rigid sheath). Automatic shut-off in the event
of electrical failure. This device must only be used with the supply provided by the manufacturer.
Hydraulic supply:
• Pressure: 1 bar (100 kPa) to 5 bar (500 kPa), recommended 3 bar (300 kPa).
Maximum recommended temperature: 40°C.
Safety:
• Mixer: supply with hot and cold water.
• Hot water supply temperature: 55 - 85°C (the difference between hot and cold water should be at least 50°C).
• Cold water temperature supply: 5 - 20°C.
• If the cold or hot water fails, the mixed water will shut off within 2 seconds.
• The anti-scalding safety is active if the temperature differential between the hot water and mixed water
is more than 15°C.
INSTALLATION
THE INSTALLER MUST ENSURE:
• THE SEAL AROUND THE RECESSING HOUSING IS WATERPROOF TO PREVENT ANY INGRESS OF WATER;
• ANY WATER ACCIDENTALLY ENTERING THE RECESSING HOUSING (E.G. CONDENSATION, RUN OFF,
LEAKS, ETC.) HAS AN EXTERNAL DRAINAGE POINT TO PREVENT ANY STAGNATION;
• THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL WALL PLATE AND THE WALL OR
THE WALL PLATE AND THE MIXER/TAP/VALVE AT LEAST ONCE A YEAR, AND MAKE GOOD IF NECESSARY.
If this advice is not followed, water may leak into the wall.
DELABIE cannot be held responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT UK: 01491 821821.
ALL OTHER MARKETS: +33 (0)3 22 60 22 74.