Télécharger Imprimer la page

Publicité

Liens rapides

Istruzioni / Instructions / Instructions De Montage / Bedienungsanleitung / Instrucciones
ART. J013BU
PARTI ESTERNE
ART. J007U
ART. J007WU
J107WU
ART.

Publicité

loading

Sommaire des Matières pour Fantini Rubinetti PARTI ESTERNE J013BU

  • Page 1 PARTI ESTERNE Istruzioni / Instructions / Instructions De Montage / Bedienungsanleitung / Instrucciones ART. J013BU ART. J007U J107WU ART. ART. J007WU...
  • Page 2: Necessary Tools

    NECESSARY TOOLS - OUTILS NÉCESSAIRES - HERRAMIENTAS NECESARIAS 17mm 2 mm 10mm TECHINCAL DETAILS - DONNÉES TECHNIQUES DATOS TÉCNICOS Minimum pressure Pression minimum Pression mínima 1 BAR Pression máxima Minimum pressure Pression maximum 10 BAR Reccomended working pressure Pression optimale de service Pression de trab.
  • Page 3 TECHINCAL DETAILS - DONNÉES TECHNIQUES - DATOS TÉCNICOS If water pressure is above 5 bar, it is advisable to install a flow restrictor upstream of the water supply to avoid vibrations and regulate temperature. Si la pression de l’ e au est supérieure à 5 bar, il est recommandé d’installer un réducteur de pression en amont de l’alimentation afin d’...
  • Page 4: Pre-Installation

    PRE-INSTALLATION - PRÉ-INSTALLATION - PREINSTALCIÓN J013BU 4-1/8" 9-3/8" 3-7/8" 3-7/8" G 1/2" ← 2-1/4" 2-1/4" 7-7/8" 2-1/4" These mixers can be used with high-pressure hot water accumulators or with instant water heaters. Ces mitigeurs peuvent être utilisés avec des accumulateurs d’ e au chaude à pression ou avec des chauffe-eau instantanés. Estos monomandos pueden utilizarse con acumuladores de agua caliente a presión o con calentadores instantáneos.
  • Page 5: Installation - Instalación

    INSTALLATION - INSTALLATION - INSTALACIÓN 10mm 17mm...
  • Page 6 INSTALLATION - INSTALLATION - INSTALACIÓN 5/32 METAL...
  • Page 7 INSTALLATION - INSTALLATION - INSTALACIÓN...
  • Page 8 INSTALLATION - INSTALLATION - INSTALACIÓN 17mm...
  • Page 9 INSTALLATION - INSTALLATION - INSTALACIÓN...
  • Page 10 TEFLON...
  • Page 12 PRE-INSTALLATION - PRÉ-INSTALLATION - PREINSTALCIÓN J007U 7-7/8" 3-7/8" 3-7/8" 5-3/4" 4-1/8" 2-1/4" 7/8" 2-1/2" 9/16"-24 UNEF 1-1/4" 9/16"-24 UNEF J007WU 7-7/8" 5-3/4" 3-7/8" 3-7/8" 7/8" 9/16" - 24 UNEF 9/16" - 24 UNEF These mixers can be used with high-pressure hot water accumulators or with instant water heaters. Ces mitigeurs peuvent être utilisés avec des accumulateurs d’...
  • Page 13 INSTALLATION - INSTALLATION - INSTALACIÓN...
  • Page 14 INSTALLATION - INSTALLATION - INSTALACIÓN...
  • Page 15 INSTALLATION - INSTALLATION - INSTALACIÓN...
  • Page 16 INSTALLATION - INSTALLATION - INSTALACIÓN 2 mm...
  • Page 17 INSTALLATION - INSTALLATION - INSTALACIÓN G1/2” 24mm G1/2”...
  • Page 18 INSTALLATION - INSTALLATION - INSTALACIÓN G1/2” G1/2” 23mm 19 mm 19 mm...
  • Page 19 INSTALLATION - INSTALLATION - INSTALACIÓN...
  • Page 20 PRE-INSTALLATION - PRÉ-INSTALLATION - PREINSTALCIÓN J107WU 7-7/8" 3-7/8" 5-3/4" 4-1/8" 2-1/4" 1" 1-1/2" G1/2" ↑ 9/16" - 24UNEF These mixers can be used with high-pressure hot water accumulators or with instant water heaters. Ces mitigeurs peuvent être utilisés avec des accumulateurs d’ e au chaude à pression ou avec des chauffe-eau instantanés. Estos monomandos pueden utilizarse con acumuladores de agua caliente a presión o con calentadores instantáneos.
  • Page 21 INSTALLATION - INSTALLATION - INSTALACIÓN...
  • Page 22 INSTALLATION - INSTALLATION - INSTALACIÓN...
  • Page 23 INSTALLATION - INSTALLATION - INSTALACIÓN 2 mm...
  • Page 24 INSTALLATION - INSTALLATION - INSTALACIÓN 24mm...
  • Page 25 INSTALLATION - INSTALLATION - INSTALACIÓN...
  • Page 26 Notes / Notes / Notas...
  • Page 27 Notes / Notes / Notas...

Ce manuel est également adapté pour:

Parti esterne j007uParti esterne j007wuParti esterne j107wu