If the oil level is between the two marking on the
dipstick, there is sufficient oil in the reservoir.
If the oil level is below the lower marking, more oil
should be added with the aid of a clean funnel.
lower marking
7. Check the oil seal and replace it if it is damaged in any
way.
8. Replace the dipstick and screw it firmly into place.
Caution! Do not tighten the screw too tightly, since this may
damage the oil seal or the thread in the cylinder cover.
Fig. 8
Fig. 9
When should I change the oil?
The first oil change should be carried out after 50
operating hours, and then every 250 operating hours.
All manuals and user guides at all-guides.com
upper marking
Oil seal
Dipstick
Changing the oil:
1. The log ram must be in its starting position.
2. Place a container under the log splitter to catch the old oil.
The container should have a capacity of at least 4 litres.
3. Unscrew the dipstick. Do not drop or lose the oil seal when
removing the dipstick.
4. Now tip the machine to empty the oil into the container.
5. Stand the log splitter on end, with the filler opening at the
top. Fig 8.
A second person will be required to up-end and
hold the log splitter.
6. Pour in the new hydraulic oil (3.5 litres) using a clean
funnel.
7. Clean the dipstick and the oil seal.
8. Check the oil seal and replace it if it is damaged in any
way.
9. Check the oil level.
10. Replace the dipstick and screw it firmly into place.
Caution! Do not tighten the screw too tightly, since this may
damage the oil seal or the thread in the cylinder cover.
Dispose of the old oil properly (local oil disposal
point). The old oil must not be poured into the
ground or drainage system, or mixed with other
waste.

Hydraulic oil

We recommend the following hydraulic oils for the log splitter:
Shell Tellus T 22
Aral Vitam Gf 22
BP Energol HLP 22
Mobil DTE 11
or equivalent
Do not use any other types of oil. The use of any other
type of oil will adversely affect the operation of the log
splitter.
S
S
Please refer to the drawing for spare parts (look at page
181).
Ordering spare parts:
- available from the manufacturer
- orders must quote the following information:
• spare parts no.
• quantity required
• model
• name of the model
Example: 360354, 1, Log splitter, ASP 5-UG