1. GENERAL INFORMATION

1. GENERAL INFORMATION
General
These are the mounting instructions for the Novy hood
shown on the cover. The manual is a separate booklet
that has been supplied with this hood. Read these in-
structions carefully before installing and commissioning
the hood. It is recommended to have one or more quali-
fi ed persons carry out the installation.
Carefully remove the hood from the packaging and
check for damage. Do not fi t the hood if it has damage.
Observe the following mounting and safety tips for
mounting:
The installation and electrical connection of the unit shall
be carried out by an authorised expert.
The manufacturer does not accept any responsibility for
any damage resulting from faulty building in or connection.
The unit is intended for household use only (preparation of
food) excluding any other domestic, commercial or
industrial use.
Safety can only be guaranteed if the unit is connected to
an earth wire in accordance with the required regulations.
Do not use an extension cord for connecting to the elec-
tricity grid.
Replace defective or damaged parts only with original
Novy parts.
Replace a damaged power cable with an original Novy
power cable.
Important before mounting:
Check all mounting materials have been supplied using
page 2 of the supplied drawings.
For easier mounting of the ceiling unit, it is recommended
to do this with at least 2 persons.
Ensure that the structure has suffi cient load-bearing
capacity.
Position the wall socket in such a way that it is behind the
ceiling unit.
Exhaust or recirculation
Before starting any mounting activities, you must have
made the choice if you are going to make an exhaust
duct to the outside or if you are going to use the hood
as a recirculation hood. In case of an exhaust duct to
the outside, carefully read the section in these mounting
instructions for installing the exhaust duct. For recircula-
tion, please separately order the recirculation kit.
Install the exhaust duct
The motor outlet has a diameter of 150 mm. It is recom-
mended to connect an exhaust duct with a diameter of
150 mm to this. A reducer is supplied with the hood. Only
mount the reducer when using an exhaust duct with a di-
ameter of 125 mm. For optimum performance of the hood
it is important to pay attention to the following points.
Circular ducts:
Use smooth, non-fl ammable pipes with an internal diame-
ter that is equal to the external diameter of the connection
nozzle of the hood. Maximally extend fl exible ducts and
cut them to size.
All manuals and user guides at all-guides.com
Flat duct:
General information:
Accessoires
Recirculation
If you opt for recirculation, Novy off ers a monoblock
recirculation fi lter which is placed in the hood.
In the manual that comes with the recirculation kit
you will fi nd the assembly and user instructions.
Article number recirculation kit: 8740400.
Other accessoires
Do not reduce the exhaust diameter. This will lower the ca-
pacity and raise the noise level.
When connecting to a short exhaust duct, it may be requi-
red to mount a non-return valve in the duct to avoid wind
blowing in.
Use a hose clamp or aluminum tape for airtight connecti-
ons.
In case of an exhaust pipe through the wall, use a wall vent.
Use fl at duct with rounded corners and with air defl ectors.
Available at Novy.
Make the duct as short as possible and with as few as pos-
sible bends to the outside.
Avoid square bends. Use rounded bends for proper air
conduction.
In case of an exhaust pipe through the outside wall passing
a cavity wall, make sure that the exhaust duct fully bridges
the cavity and slightly declines to the outside.
In case of an exhaust pipe through the roof, use a dou-
ble-walled roof passage with suffi cient width.
Never connect to a fl ue duct.
Make sure that suffi cient air is supplied. Fresh air can be
supplied by slightly opening a window or an outside door
or by installing an inlet grate.
906291 Hose clamp adjustment range Ø60-215 mm
906292 Aluminum tape roll 50 m
906178 Aluminium blinds outside wall grille
906432 Non-return valve TSKE150 Ø150 mm
990030 Kit for valve control or external lighting
8740100 Ornamental chimney fi xed
8740150 Ornamental chimney telescopic
8740400 Recirculation kit