Leak testing
Never use a naked flame to check for leaks.
Never leak test while smoking.
The gas connections on this appliance are leak test-
ed at the factory prior to shipment.
This appliance needs to be periodically checked
for leaks and an immediate check is required if the
smell of gas is detected.
• Make a soap solution using 1 part of liquid
dish-washing soap to 3 parts water. The soap
solution can be applied with a soap bottle, brush,
or rag to the leak tested points shown in the figure
above.
• The valve of the gas cylinder should be in the OFF
position at this point of the leak test. Once the
soapy solution is applied to the gas connections,
the valve of the gas cylinder needs to be turned to
the ON position.
• Soap bubbles will begin to form in the soapy solu-
tion if a leak is present.
Gas requirements
• Never use a gas cylinder with a damaged body,
valve, collar, or foot ring. A dented or rusty gas
EN
tank may be hazardous and should be checked out
by a gas supplier.
• Never connect this appliance to an unregulated
gas source.
Connecting to a gas cylinder
• Recommended to use 9 kg gas cylinder or refer to
your gas supplier for suitable gas cylinder.
• Approved gas regulator is used according to ap-
pliances categories and countries listed in data
plate. Approved flexible hose would be changed
when the national conditions require it.
• Assembly of the tubing must be conducted by
some qualified tuber of destination countries.
• Only change gas cylinders outdoors or in a well
ventilated area away from naked flames and any
other source of ignition (candle, cigarettes, other
flame producing appliance....).
12
All manuals and user guides at all-guides.com
• In case of a leak, turn off the gas supply. Tighten
any leaking fittings, then turn the gas supply on
and recheck.
• When the appliance is not in use, turn the gas cyl-
inder OFF.
• Always perform a leak test on gas connections
whenever a cylinder is connected. If bubbles form
in the leak test solution, do not use. Never use a
flame to test for leaks.
• The gas cylinder must always be used in an up-
right position.
• Close the heater control knob by turning fully
clockwise.
• Close the gas cylinder tap and then attach the reg-
ulator onto the gas cylinder.
• Tighten all connections firmly and with a spanner
where appropriate. The cylinder should be located
on the cylinder base.
• Check for leaks at all joints using soapy water. If
a leak is found, tighten the joint and then re-test.