NOTICE
1. The product should only be powered by a UL listed power supply Regulated Power Limited power source.
2. Installation Location: Indoor Dry.
Performance level:
Destructive: Level I
Endurance: Level II
Installation & wiring in compliance with ANSI/NFPA70 requirements
Wiring must be insulated to avoid outer cable damage and will affect the installation distance.
Terminal: 12~22AWG
3. Wire power switch between DC source voltage and magnet. Wiring between AC and magnet will take a longer
time to de-energize the magnet resulting in residual magnetism (see below).

Installation Tips

1.
During installation and testing, minimize touching the lock face and clean with a soft, dry cloth when finished. DO NOT use sand paper.
2.
A rust inhibitor can be applied to the armature/strike plate and maglock assembly face.
Line Security: Level I
Standby power: Level I
Printed Circuit Board Schema�c