Troubleshooting Guide - Cavavin C-73WBVC Manuel D'instruction

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

You can solve many common beverage center problems easily, saving you the cost of a possible
service call. Try the suggestions below to see if you can solve the problem before calling the servicer.
PROBLEM
Not plugged in.
Cellar does not
The appliance is turned off.
operate.
The circuit breaker tripped or a blown fuse.
External environment may require a higher
setting.
Cellar is not cold
The door is opened too often.
enough.
The door is not closed completely.
The door gasket does not seal properly.
The room temperature is hotter than normal.
A large amount of contents has been added
The compressor
to the cellar.
turns on and off
The door is opened too often.
frequently.
The door is not closed completely.
The temperature control is not set correctly.
The door gasket does not seal properly.
In order to circulate the air and maintain the set temperature inside the cabinet the fans must
cycle on and off even when the compressor is off. The fans will cycle ON and OFF while the
The fans turn on and
compressor is off approximately every 10 seconds, this is called "Semi-speed status". This
off frequently.
cycle is normal and meant both to circulate the air as well as ensure the continued
operational status of the fans. If the fan stops completely and does not complete this cycle
the fan is non-operational.
Not plugged in.
The light does not
The circuit breaker tripped or a blown fuse.
work.
The light button is "OFF".
The cellar is not levelled
Vibrations.
The bottles are vibrating.
There is an object under the Cellar.
The cellar seems to
make too much
The Cellar is not level.
noise.
The Cellar is not level.
The door was reversed and not properly
The door will not
installed.
close properly.
The gasket is dirty.
The shelves are out of position.
Error Code:
A sensor has failed.
E0-E1-E2
All manuals and user guides at all-guides.com

TROUBLESHOOTING GUIDE

POSSIBLE CAUSE
28
SOLUTION
Plug the unit.
Press
to turn on the unit.
Check the breaker and/or fuses.
Check the temperature control setting.
Close the door properly.
Check the door gasket.
Close the door properly.
Check the door gasket.
Plug the unit.
Check the breaker and/or fuses.
Unlock the control panel: press and hold
both the
and
buttons for 3 seconds the
control panel will beep and blink once
indicating that the control panel is active and
the settings can be changed.
Check to assure that the Cellar is level.
Make sure the bottles don't touch each
others.
Remove the object.
Level the cellar.
The rattling noise may come from the flow of
the refrigerant, which is normal. As each
cycle ends, you may hear gurgling sounds
caused by the flow of refrigerant in your
cellar. Contraction and expansion of the
inside walls may cause popping and
crackling noises.
Level the cellar.
Close the door properly.
Clean the door gasket.
Place the shelves properly.
Contact us for a service call.