Faber VELVET Mode D'emploi page 5

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TOOLS NEEDED FOR INSTALLATION
• Saber Saw or Jig Saw
• Drill
• 1 1/4" Wood Drill Bit
• Pliers
• Phillips Screwdriver
• Wire Stripper or Utility Knife
• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape
PARTS SUPPLIED FOR INSTALLATION
• 1 Backdraft Damper
• 1 Literature Package
PARTS NEEDED FOR INSTALLATION
• 2 Conduit Connectors
• Power Supply Cable
• 1 Wall or Roof Cap
• All Metal Ductwork
OPTIONAL ACCESSORIES AVAILABLE
• Charcoal Filters
For non-vented installations only,
replace charcoal filters as needed
part # FILTER1
VERTICAL
DUCTING
FIGURE 1
For recirculating installations (FIGURE 3), Charcoal Filters are necessary. Open the comfort panel by turning the knobs to the
right, slide open the glass visor, and remove the grease filters and set aside. Attach one charcoal filter to each end of the blower.
Each charcoal filter attaches to the of the side of the blower. Rotate the filter clockwise to install and counterclockwise to remove
(FIGURE 3A). Replace the grease filters and reattach the comfort panel. Some ductwork must be installed to exhaust the
rangehood back into the kitchen, either at the top of the cabinet or at the face of the soffit. Using a plastic vent grate to cover
This duct work must not terminate into a dead air space
the duct opening.
vent grate
cabinet
6" round
duct
hood
The Velvet slideout rangehood is designed to offer wide flexibility of installations.
The rangehood can be ducted through a 6" round vent. The unit can also be
installed in a recirculating configuration. The unit comes standard in the top
venting position. FIGURE 3 shows recirculating installation.
The Velvet requires 6" round ductwork. To ensure that the blower performs to its
highest possible capacity, ductwork should be as short and straight as
possible.
The ductrun should not exceed 50 feet if ducted
with the required minimum of 6" round duct.
Calculate the length of the ductwork by adding the
equivalent feet in FIGURE A for each piece of duct
in the system An example is given in FIGURE B.
For best results, use no more than three 90°
elbows. Make sure that there is a minimum of
24" of straight duct between elbows if more
than one is used. Do not install two elbows
together. If you must elbow right away, do it
as far away from the hood's exhaust opening
as possible.
FIGURE 2
RECIRCULATING INSTALLATIONS
ceiling
soffit
cabinet
FIGURE 3
PLAN THE DUCTWORK
For direct rear venting (FIGURE 2), you
must change the blower position. Remove
the 12 screws that hold the metal housing
HORIZONTAL
to the rangehood body. Rotate the blower
DUCTING
90 degrees toward the back and then flip it
over 180 degrees. Be sure that the power
supply cable is properly positioned. Replace
all screws, making sure that they are firmly
fastened.
vent grate
6" round
duct
hood
45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap
FIGURE A
9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap
Total System
FIGURE B
.
ceiling
FIGURE 3A
Version 09/12 - Page 5
3.0 feet
5.0 feet
12.0 feet
0.0 feet
9.0 feet
10.0 feet
0.0 feet
19.0 feet

Publicité

Table des Matières
loading

Table des Matières