6. Trouble Shooting
Having trouble?
Noise is louder than specifications.
7. Specifications
Model
Power source (voltage <V>/Frequency<Hz>)
Rated Input (Indoor only)
Rated Current (Indoor only)
Heater
Dimension (Height)
Dimension (Width)
Dimension (Depth)
Fan airflow rate (Low-High)
Noise level (Low -High)
Net weight
Model
sensible
Cooling Capacity
latent
Heating Capacity
Total electric power input
Sound power level
(per speed setting, if applicable)
(EU)2016/2281
PCA-M71HA Series
~/N 230/50
<kW>
0.10/0.10
<A>
0.43/0.43
<kW>
-
<mm>
280
<mm>
1136
<mm>
650
<m
/min>
16-18
3
<dB>
37-39
<kg>
42
PCA-M71HA Series
P
<kW>
5.25
rated,c
P
<kW>
1.85
rated,c
P
<kW>
8.10
rated,h
P
<kW>
0.10
elec
L
<dB>
57-55
WA
Here is the solution. (Unit is operating normally.)
The indoor operation sound level is affected by the acoustics of the
particular room as shown in the following table and will be higher than
the noise specification, which was measured in anechoic room.
High sound
absorbing rooms
Broadcasting
Location
studio, music
examples
room, etc.
Noise levels
3 - 7 dB
Low sound
Normal rooms
absorbing rooms
Reception room,
Office, hotel
hotel lobby, etc.
room
6 - 10 dB
9 - 13 dB