LUXOMAT
Thank you for purchasing the LUXOMAT
You have chosen a quality product from BEG that
was manufactured, tested and packaged with the
greatest of care.
Please read these instructions prior to mounting your
unit.
We reserve the right to make technical changes to
improve the product.
Caution: have all work involving the 230V mains
supply carried out by a qualified electrician! Before
starting disconnect the mains!
Please be aware, that the LUXOMAT
not suitable as an intrusion detector, since it is not
equipped with a tamper contact according to VDS
regulations.
LUXOMAT
®
RC-plus
white
130°
92001
230°
92002
280°
92003
IR-RC-Mini infrared remote control
Part.Nr. 92090 (included)
IR-RC infrared remote control
Part.Nr. 92000
Holder for IR-RC remote control
Part.Nr. 92100 (included)
BEG is the world's fist manufacturer to achieve remote
IR-RC-Mini (included)
RC-plus.
®
RC-plus is
®
Part.-Nr. / Colour
black
brown
92021
92011
92022
92012
92023
92013
R C - p
®
adjustment of a movement detector using an infrared
remote control.
The LUXOMAT
RC-plus can still be set in the tradi-
®
tional manner using adjustable dials, and put into
operation.
More functions can be set using the remote control
(see chapter IR remote control.
Mounting
Optimum sensitivity is achieved by mounting the unit
in a position lateral to the walking detection. The
optimum mounting height is 2.5m (figure 2 point 3).
The range is lowered accordingly if the unit is mounted
at a lower height.
Œ
Distance from optical sources of interference 5m
minimum.
The unit should be mounted at a distance of 5
to 6m from the connected light, (1+2) use the
cover-up clips supplied if necessary. (Fig.13)

Mount the lights above the LUXOMAT
and not underneath it.
Ž
Protected mounting location
The LUXOMAT
from the rain and direct sunlight in order to
avoid unwanted switching on of the unit due to
environmental influences.

Mounting of several LUXOMAT
The coverage of the individual units must overlap
in order to guarantee complete monitoring.

Wall/ceiling mounting
Twist the sensor element and terminal box 180°
in a clockwise direction away from one another.
The LUXOMAT
ing without an additional device.
For wall mounting twist back 180° in a counter
clockwise direction.
Fixing of the wall terminal box and electrical
connection
The wall terminal box of the LUXOMAT
is identical to that of the LUXOMAT
Both devices can thus be used to replace one
another without any problem. Their connections
are compatible.
25
I R - R
l u s +
RC-plus should be protected
®
RC-plus
®
can then be mounted on the ceil-
®
2000-Vario.
®
Ref. to drawings and diagrams.
C
RC-plus
®
RC-plus
®