WMBUS Pulse - Guide utilisateur / User guide version V2.2.0
Table of AT commands:
Command
+++
Input request in command mode
ATPIN <PIN>
Gives access to AT commands if register S304 is
different of 0
AT/V
Feeds back the version of the APPLICATIF and
RTU software
AT/N
Feeds back the type of network
ATS<n>?
Feeds back the content of the n range
AT/S
Edits the content of all of the user ranges in the
form of a list.
ATS<n>=<m>
Transfers the m VALUE to the n range
AT&W
Saves the current configuration to non-volatile
memory.
ATO
Exit command mode
ATT63 PROVIDER
Unblock the operating range
Example of a set of commands and corresponding responses that can be seen on the terminal:
Syntax
of the order
+++
Input request in command mode
ATS201=0
Change frame format
ATT63 PROVIDER
Unblock the operating range
ATS201=0
Change frame format
ATS200?
Return value of S200
AT&W
Memory request for the state range
ATO
Output request in command mode
Interpreting the previous example: the user wants to modify the frame format register (S201)after having made an unauthorized command
(answer E), and then the network registers are unlocked in order to modify this register. A read of register S200 (WMBUS channel) is done and
the parameters are saved before exiting. When exiting command mode, the product starts a new transmission cycle.
Description
Description
Reply example
CONNECTING... <cr><lf>
CM<cr><lf>
APP_8230EAA_PRG1706_V01.02.02:RTU_RTU_WM-
BUS_868_PRG_1601_V00.00.03
Or
APP_8181AAA_PRG1701_V01.00.02:RTU_8120AAB_
PRG_1701_V01.00.01
"LoRa" or "SIGFOX" or « WMBUS »
Sn=y where y represents the content of the n range
/
«O»<cr><lf> if Ok, «E»<cr><lf> if error, «W»<cr><lf> if
coherency error
«O»<cr><lf>, «E»<cr><lf> if coherency error
«O»<cr><lf>, «E»<cr><lf> if coherency error
«O»<cr><lf>
Response Syntax to Next Line
CONNECTING...
CM
E -> This command is not validated (register no unlocked)
O
O
S200=24
O
O
FR
EN
Page
73
of 99