10 Amp Fully Automatic Battery Charger
For 12 Volt Batteries
Read warning on back and instruction manual
Model MKC-10
Input: 120 VAC 2 AAC 60 Hz
Output: 10 ADC 12 VDC
OFF - ON SWITCH
Make sure On/Off switch is in the Off position when connecting
and disconnecting charger to battery.
AUTOMATIC CHARGING
When the battery reaches the full charge state, charge current is
turned off and the charger switches to the maintainer mode of op-
eration. This action occurs when the charge tapers down to ap-
proximately 5 Amps. In this state the battery voltage is constantly
being monitored. When the battery voltage drops to a predeter-
mined value charge will turn on for a few seconds replacing the
small amount of energy that was lost while the charge current was
at 0 Amps.
POWER ON INDICATOR
The Power On LED Indicator will glow green when the unit is
turned ON and it is plugged into 120 Volt electrical outlet. Charg-
ing begins once clamps are connected to the battery.
BATTERY CHARGER CONTROLS
BATTERY CHARGER CONTROLS
FIGURE 3 - CHARGER CONTROLS
ON
OFF
CHARGE COMPLETE INDICATOR
When the battery reaches the full charged state, the right LED
indicator light will glow green.
NOTE: As the battery approaches the full charge state the LED
will fluctuate on and off between CHARGING and CHARGED. For
the average size automotive battery, allow 5 to 10 minutes for the
battery to stabilize.
REVERSED CONNECTION INDICATOR
If clamps are attached incorrectly to the battery posts, example:
negative to positive or positive to negative, the right LED will glow
red. When connected properly, no LED will glow.
3
RED
REVERSED
CONNECTION
GREEN
POWER ON
CHARGING
COMPLETE
MADE IN U.S.A.