IMPORTANT: The instruction manual you are holding includes essential information on the safety measures to be implemented for
installation and start-up. Therefore, the installer as well as the user must read the instructions before beginning installation and start-up.
Keep this manual for future reference.
To achieve optimum performance of the Standard Floodlamp follow the instructions provided below:
1. CHECK THE PACKAGING:
Inside the box, you will find the following components. (Fig. 1):
BY PASS feeder:
1.
Cover nut.
2.
Cover.
3.
Cover nut key.
4.
Body unit.
Bag.*
* Consult the contents on pp. 15-17.
2. MAJOR CHARACTERISTICS:
This chlorine/bromine feeder has been designed to insure proper disinfection of swimming pool water. The model can be
easily adapted to any swimming pool installation of up to 180 cu. Metres. More than one may be installed for larger
volumes.
This feeder must be installed on the pool feedback line, after the filtration equipment and/or the heating system, water
cleaning system or any other equipment or system.
It only operates with compact Trichlorine or Bromine tablets. Never use any type of chemical product in the feeder.
By regulating the control valve and the amount of tablets available inside the feeder, you can easily adjust the amount of
chlorine/bromine required in order to maintain the suitable residual concentration in the swimming pool.
3. INSTALLATION:
3.1 INSTALLATION OF BY-PASS MODEL:
1.
Install the inlet pipe between the pump and the filter. And the outlet pipe to the return pipe, installation should
always be located after the heating system (heat pump or interchanger). If there is no system of this type, the feeder
should be installed after the filter (Fig. 2). Do not install in copper tubing.
2.
A valve must be installed on the water intake line to the feeder. Use adhesive to connect the intake and outlet
fittings to the Ø20 PVC tube (Fig. 3) place the latter vertically and make sure that there is no excess glue remaining
that might block the openings.
3.
A valve must be installed on the water outlet line from the feeder. Use adhesive to connect the intake and outlet
fittings to the Ø20 PVC tube (Fig. 4) place the latter vertically and make sure that there is no excess glue remaining
that might block the openings.
4.
Connect the lower drain to the swimming pool return.
3.2 CHECKING THE DOSIFIER FOR WATERTIGHTNESS
Caution: When the dosifier has been assembled, but before placing the Trichlorine or Bromine tablets inside, proceed to
check for watertightness, as follows:
1.
Open the dosifier lid (Fig. 5).
2.
Close the lower drain lid (Fig. 6).
3.
Fill the dosifier with water manually, taking care not to leave any air inside.
4.
Close the dosifier lid and connect the upper drain.
5.
Start up the filtering equipment.
6.
Open the outlet valve and the inlet valve allowing the water to flow through the dosifier.
7.
After a few minutes, check there is no water loss.
3.3 STARTING UP THE DOSIFIER
1.
Place the Trichlorine or Bromine tablets.
2.
Close the dosifier lid.
3.
The upper drain lid (Ps in Fig. 6) must be closed.
4.
Open the outlet valve to a maximum of 2 turns.
5.
Open the inlet valve regulating it to obtain residual free Chlorine (Fig. 7) of between 0.5 and 2 ppm in the pool
water.