4.6 SET/RESET mode
manual reset via the red
SET/RESET key and
electrical reset via the SET/
RESET input
no reset (red SET/RESET
key and SET/RESET input
locked)
only electrical reset via the
SET/RESET input
only manual reset via the red
SET/RESET key
4.7 SET value
The device will be set to the
set point by pressing the red
SET/RESET key or activating
the SET/RESET input.
SET value 0...999 999 or
99.59.59 (number of decimal
places depends on the deci-
mal point option)
4.8 End of programming
The programming routine is
repeated once more. The
values set until now can be
checked and modified.
The programming routine
wil be left and all values set
will be stored as new pa-
rameters.
Afterwards the device is
ready for operation.
*0, 0.1, 0.01, 0.001 means: time measurement
in 0, 0.1, 0.01, 0.001 time units
www.kuebler.com
5. Technical data
Supply voltage
AC power supply:
100...240 VAC/max. 8 VA
Tolerance ±10%, 50/60 Hz
ext. fuse protection: T 0.1 A
DC power supply: 10...30 V DC/max. 50 mA
with inverse-polarity
protection
SELV, CLASS II
(Limited Power Source)
ext. fuse protection: T 0.1 A
Display:
6 digits, red 7 segment
LED display, height 14 mm
Data retention:
EEPROM
Polarity of the inputs:
Programmable, npn or pnp
for all inputs
Input resistance: appr. 5 kOhm
Count frequency CODIX 541:
AC power supply:
Input level:
typ. Low Level:
typ. High Level:
Fmax:
CntDir
UpDown
Up.Up
Quad1
Quad2
Quad4
DC power supply: 24 12 V DC 10...30 V DC
Input level:
typ. Low Level:
typ. High Level:
Fmax:
CntDir
UpDown
Up.Up
Quad1
Quad2
Quad4
100...240 VAC ±10%
Standard 4...30 V DC
2.5 V
1.0 V
22.0 V
4.0 V
kHz
kHz
60
50
25
25
25
25
25
25
25
25
15
15
Standard
4...30 V DC
2.5
2.0 V
1.0 V
22.0
10 V
4.0 V
kHz
kHz
kHz
60
20
8
25
15
8
25
15
8
25
15
8
25
15
8
15
15
8
Page 9