Only an expert may replace a damaged power pack. Danger of electric shock.
Please ensure that all electric connections, connection cables and possible exten-
sion cables are regulatory and comply with the operating manual.
You may only use a 230 Volt / 50 Hz (10/16 A) earthed socket of
the public supply net for the supply of the power pack. Never
attempt to operate the appliance with a different voltage. The
appliance is only suited for operation in closed rooms.
Only pull the power pack out of the socket by its casing, never pull
on the cable.
Never plug-in or unplug the power pack appliance with wet hands.
Electric appliances do not belong in the hands of children. Be espe-
cially careful in the presence of children. Children might try to insert
objects into the appliance. Danger of mortal electric shock!
Always pull the power plug out of the socket:
- before cleaning the appliance
- during thunderstorms
- if you are not going to use the appliance for longer periods of time
Never place the appliance on an unstable surface. When the appliance falls down, it
might hurt persons or become damaged.
Do not leave the packaging material lying around. Plastic foils respectively bags and
polystyrene parts etc. are dangerous for children. Danger of suffocation!
Make sure that the power cable does not get squashed or damaged by sharp edges
when installing the appliance.
Always pull the power plug out of the socket
- before cleaning it
- during thunderstorms
- if you are not going to use the appliance for longer periods of time
24
All manuals and user guides at all-guides.com
Technical Data
Power Pack:
Operating voltage:
Power consumption:
Output voltage:
Output current
Mixing Desk:
Operating voltage:
Power consumption:
Input:
Input sensitivity
Output:
Output level
Frequency range:
Distortion factor:
Channel separation:
SN ratio:
Talk over:
Ambient Conditions
Operating temperature range:
Relative air humidity:
230 VAC / 50 Hz
approx. 10 W
12V AC
300 mA
12 VAC / 50 Hz
max. 250 mA
Microphone 1 mV / 600 Ohm
PHONO 3 mV / 47 kOhm
LINE 150 mV / 100 kOhm
MASTER 770 mV / 600 Ohm
RECORD 400 mV / 600 Ohm
Headphones 100 mV / 8 Ohm
20 Hz – 20 kHz (+/ - 1 dB) / (RIAA
+/ - 2 dB)
< 0.1 dB
> 45 dB
Microphone 70 dB
PHONO 70 dB
LINE 75 dB
-12 dB at 1 kHz
+10 up to +50 °C
< 90 % (non-condensing)
37