Indicator light
Top: GREEN is on
Middle: GREEN is on
Bottom: RED is on
Testing the voltage of a 12 V battery (Type lead acid)
If the energiser is operating in SLOW, NIGHT SAVE, HALF POWER or FULL POWER mode and the
battery voltage falls below 10.5 V, the energiser will automatically switch OFF.
If the battery voltage then increases to more than 11 V, the energiser starts operating in the
mode indicated by the rotary switch. You can test the battery voltage at any time. Turn the rotary
switch to BATTERY TEST mode. The three indicator lights now show the battery voltage.
Indicator light
Top: GREEN is on
Middle: GREEN is on
Bottom: RED is on
Estimated minimum battery life
P 20
P 40
P 60
Energiser storage
Store the energiser in a cool, dry place when it is not in use.
Disconnect the battery to prevent the battery discharging.
If the battery is a 12 V lead acid type, the battery must be recharged every six months OR
kept on float charge.
44
Voltage 9 V battery
7.1 V or more
7.1 - 5.5 V
5.5 V
less than
Voltage 12 V battery
12.5 V or more
12.5 - 12.1 V
less than 12.1 V
9 V/55 Ah
9 V/90 Ah
90 days
150 days
75 days
120 days
50 days
Remaining capacity
Zinc-carbon battery
75 %
or more
8 - 75 %
8 %
less than
9 V/175 Ah
280 days
235 days
80 days
150 days
Remaining capacity
Alkaline battery
1 % or more
0 - 1 %
0 %
Remaining capacity
Lead acid battery
60 % or more
10 - 60 %
less than 10 %
12 V/35 Ah
75 days
60 days
50 days