Optional:
Connecting a 12 V battery (Type lead acid)
A 12 V battery connection cable can be purchased from your local PATURA dealer. Instructions
for connecting a 12 V battery to an energiser are supplied with the connecting cable.
Connecting to an electric fence
The energiser automatically detects whether a 9 V or 12 V battery is connected.
1. P ush earth stake fully into firm ground. If the ground is dry or sandy, performance can be
improved by using a longer earth stake that can be obtained from your fencing supplier.
2. C onnect the green earth lead to the earth terminal (
earthing system.
3. C onnect the red fence lead to the fence terminal (
Ensure there is a good connection.
Operating the PATURA P 20 energiser
Switching on and off
1. T o switch on the energiser, turn the rotary switch clockwise (right) to
The energiser will deliver a pulse once every 1.5 seconds.
The red indicator light flashes to indicate an output pulse.
2. T o switch off the energiser, turn the rotary switch anti-clockwise (left) to
The red indicator light stops flashing.
Operating the PATURA P 40 and P 60 energisers
There are six operating modes to select from, depending on your requirement.
Use the rotary switch settings to select an operating mode.