12/16
Bosch Rexroth AG Hydraulics
Affectation des broches de la carte asservie VT-MAC8-1X/K-AX4
X1
Broche
Rexroth
1
address
2
S1
3
4
5
6
X1
7
8
9
X2.1
10
11
12
X2.2
13
X2.x
Broche INC
X2.3
1
2
3
4
5
6
X2.4
7
24V OK RUN BUS
8
9
10
11
AX-4
12
13
14
15
E/S analogiques sur la carte asservie
Broche Description
I
1
Entrée courant/tension ±20 mA / ±10 V
in
C
I
2
14
Entrée courant/tension ±20 mA / ±10 V
in
C
AGND
Analog Ground
I
3
15
Entrée courant/tension ±20 mA / ±10 V
in
C
I
4
Entrée courant/tension ±20 mA / ±10 V
in
C
AGND
16
Analog Ground
IU
1
Entrée courant/tension 0...20 mA / ±10 V
in
A
IU
1
17
Entrée courant/tension 0...20 mA / ±10 V
in
B
IU
2
Entrée courant/tension 0...20 mA / ±10 V
in
A
IU
2
18
Entrée courant/tension 0...20 mA / ±10 V
in
B
AGND
Analog Ground
IU
3
19
Entrée courant/tension 0...20 mA / ±10 V
in
A
IU
3
Entrée courant/tension 0...20 mA / ±10 V
in
B
IU
4
20
Entrée courant/tension 0...20 mA / ±10 V
in
A
IU
4
Entrée courant/tension 0...20 mA / ±10 V
in
B
AGND
21
Analog Ground
U
1
±10 V
out
U
2
22
±10 V
out
U
3
±10 V
out
U
4
23
±10 V
out
AGND
Analog Ground
I
1
24
±20 mA
out
I
2
±20 mA
out
I
3
25
±20 mA
out
I
4
±20 mA
out
Connecteur de transmetteur
SSI
/Ua 2
+Clk
Ua 0
/ Ua 0
Ua 1
/ Ua 1
–Clk
Ua 2
–Data
0 V
0 V
+Data
Réservée
Réservée
n. c.
n. c.
Réservée
Réservée
n. c.
n. c.
S1
Adresse
Logement
2
Slot 2
3
Slot 3
4
Slot 4
5
Slot 5
6
Slot 6
7
Slot 7
8
Slot 8
0 - 1 Interdit
9 - F Interdit
Avis:
Ne pas attribuer les broches marquées "réservée".
VT-MAC8 RF 30156/03.12
Avis:
Adresser la carte en
fonction du logement.