Anleitung KCT 200
Setting for covered cuts:
Lower the table (1) to its bottom position.
Undo the thumb screw (21) and remove the saw
blade guard (2).
Slacken the two hexagon socket-head screws
(24) with the supplied socket wrench (35).
Move the splitter (5) to its bottom position.
Adjust the splitter (5) so that the distance
between the saw blade (4) and the splitter (5)
equals 3 - 5 mm. The tip of the splitter has to be
2 mm below the tip of the top saw tooth.
Tighten the two hexagon socket-head screws
(24).
Important!
After making a covered cut it is imperative to
return the splitter to its top position and to refit
the guard hood (see 7.3).
The splitter has to be adjusted each time the
saw blade is changed.
7.3 Fitting the saw blade guard (Fig. 3)
Move the splitter (5) to its top position.
Take the thumb screw (21) out of the saw blade
guard (2).
Mount the saw blade guard (2) on the splitter (5)
and align.
Use the thumb screw (21) and the nut (z) to
fasten the saw blade guard (2) to the splitter (5).
8. Using the saw
8.1 Switching on and off (Fig. 4)
4
09.11.2001 10:35 Uhr
Seite 13
Push the lock button (a) to the right.
Swing open the cover (b).
The saw can be switched on by pressing the
green pushbutton (c).
Wait for the saw blade to reach its maximum
speed before beginning to saw.
The red pushbutton (d) has to be pressed to
switch off the saw.
The outer cover (b) can be closed and secured
with a padlock to prevent the saw from being
switched on without permission (e) (child guard).
8.2 Parallel stop (Fig. 5)
5
The parallel stop (7) has to be used when slitting
wood pieces.
Slide the parallel stop (7) to the right or left side
of the saw table (1).
Make sure that the lugs of the clamping device
(33) latch in place underneath the saw table (1),
and check that the two toggle levers (13) are in
their bottom positions.
The parallel stop (7) can be set to the required
dimension with the help of the scale engraved
on the saw table (1).
Important: Please note that the scale is
adjusted to the centre of the saw blade, i.e.
1.3 mm have to be deducted from the value
indicated on the engraved scale.
To fix the parallel stop (7) on the saw table (1),
push the two toggle levers (13) upwards.
GB
13