Spark Plug; Photocell; Fuel Filter - Mi-T-M Corporation MH-0075-0M10 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SPARK PLUG:

Clean and re-gap every 600 hours of operation, or replace
as needed.After removing the Spark Plug, clean the ter-
minals with a wire brush. Re-gap the terminals to 0.140"
(3.5mm).
NEVER
LEAVE
HEATER
BURNING OR WHILE CONNECTED TO A FUEL
SOURCE.
IMPROPER MAINTENANCE CAN LEAD TO POOR
COMBUSTION AND SOOT PRODUCTION

PHOTOCELL:

The Photocell should be cleaned at least once per heating season or more depending on conditions.
Use a cotton swap dipped in water or alcohol to clean the lens of the Photocell. Note the proper Photo-
cell position as noted.
Photocell
Installing Photocell
1.)Incorrect
2.)Correct

FUEL FILTER:

The Fuel Filter should be cleaned at least twice per heating season by rinsing it in clean #1-K kerosene.
Contaminated fuel could make this necessary immediately.
NOTE: To remove the filter from model MH-0075-0M10, turn filter 90° clockwise. To remove the filter from models MH-0135-
0M10 / MH-0190-0M10 / MH-0215-
0M10, turn filter 90° counter-clockwise.
16
*Always follow manufacturer instructions*
MAINTENANCE
UNATTENDED
Photocell
Lens
Side Cover
Power Switch
*AAA Rent-All 225-291-1356*
Spark Plug
WHILE
Burner Head
Photocell
Wire
(MH-0075-0M10 only)
Photocell Wire
Circuit Board
Fuel Filter
Screw
Fuel Line
Power Switch Wire
Ignitor Wire
Gap
Circuit Board
Kerosene Portable Heaters Manual

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mh-0135-0m10Mh-0190-0m10Mh-0215-0m10

Table des Matières