Troubleshooting

Noise:
 If abnormal noise occurs, request service assistance.
 Operating sounds from compressor, condenser fan and interior fan are normal.
 If sheet metal parts, front panels or panels in front of the compressor compartment
are making noise, these might be open. Close the panels.
Frosting inside compartment:
 Ambient humidity too high.
 The door is opened too often.
 The door is left open for too long.
 Damaged door gasket.
Poor cooling performance:
 Ambient temperature too high (above +43 °C).
 The door is opened too often and/or open for too long.
 The door is left open.
 Damaged door gasket.
 Room temperature setting too high.
 Counter too packed with foods - air inlet/outlet blocked.
 Condenser mesh filter is clogged.
 Warm or hot foods inside.
 Defrost in progress. The room temperature may rise temporarily during the defrost
cycle, but it will not affect the foods inside.
Some of the foods are frozen:
 Counter too packed with foods - air inlet/outlet blocked.
 Room temperature setting too low.
Condensation around the door:
 Ambient humidity too high.
 The door is not closed tightly.
 Damaged door gasket.