Monitoring On Noise; Motion Detector (Combi); Warranty - Leitronic AG bebetel bebetelCLASSIC Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10.1 Monitoring on noise

Problem
No activation

10.2 Motion detector (COMBI)

Problem
WALK-test LED is on, but
bébétel® does not call
WALK-test LED has been
turned on, but is not light up
Call with three beeps without
prior movement (WALK-test
LED has been off all the time)
Call with two or three beeps was
triggered although the motion
detector was temporarily
deactivated

11 Warranty

Dear Customer
®
Each bébétel
is manufactured and tested according to stringent quality rules. If you have any claim, Leitronic
AG will guarantee additional to warranty against your vendor, to repair device without any labour or material
costs, for 2 years after date of purchase. Warranty is only given if bébétel
above instructions. Warranty will not be given under the following circumstances:
If there is no invoice or receipt with date of purchase, vendor's name and serial-No.
These documents have been changed or modified.
If serial-No on type label has been changed, cleared, removed or modified in any way.
If any repair, modification or other adaptation has been carried out by unauthorised persons or companies.
Damage due to tampering with device.
Damage due to external influence (Lightening, water, fire..).
Please contact us before returning a device on our INFO-Line +41 (0)56 648 40 40 or check our
interactive troubleshooting pages on: www.bebetel.com. Defected units are very rare!
LEITRONIC AG
Engeloostr. 16
CH-5621 Zufikon
Switzerland
54
Cause and/or remedy
After power on bébétel® remains inactive for a waiting period of two
minutes so you can leave your room without triggering a call. If you
want to skip this period you can proceed as follow: Press key
you directly change to monitoring mode, where you can test response
sensitivity
A call will be triggered depending on position of sensitivity switch. As
long as noise level is exceeded the indication LED shines
6.6.1.
Cause and/or remedy
Alarm unit is still in the inactive waiting period after being switched on
or after a call
Motion detector is temporarily deactivated
No voltage supplied to motion detector (
AC-adapter and mains)
Voltage supply has not yet lasted for two minutes (warm up time of
motion detector)
No voltage supplied to motion detector (
AC-adapter and mains)
Motion detector has been connected or disconnected after the alarm unit
had been switched on
Voltage supply of motion detector interrupted
Function switch has been shifted to OFF or PROG after deactivation.
Tel +41 (0)56 648 40 40
6.3.
www.leitronic.ch
check cable, TWIN-adapter,
check cable, TWIN-adapter,
®
has been handled according to the
.9
and

Publicité

Table des Matières
loading

Produits Connexes pour Leitronic AG bebetel bebetelCLASSIC

Ce manuel est également adapté pour:

Bebetel bebetelextraBebetel bebetelmobile

Table des Matières