TROUBLE-SHOOTING
Please note: the information in the table below and the action to take is intended for the use
of the assistance centre personnel and others qualified to install/maintain the equipment.
Error message
Error 1
Error 2
Error 3
Error 4
Error 5
Error 6
Error 7
For any situations not covered in this table, consult your approved assistance centre or contact the company
direct.
The data and features referred to are not binding on EFFEGIBI and the company reserves the right to make any appropriate changes without having to give prior warning or replace this manual.
The data and features referred to are not binding on EFFEGIBI and the company reserves the right to make any appropriate changes without having to give prior warning or replace this manual.
TOPKAPI OPERATING AND MAINTENANCE MANUAL
Meaning
C o m m u n i c a t i o n
error.
No communication
between
control panel and
the boiler.
The boiler fills up
too quickly.
The
boiler
not fill up within the
stated time.
The boiler does not
empty within the
stated time.
New peripheral
device recognised.
Temperature probe
is broken.
Cause
No power to one
of the components
and
it
is
not
connected.
No power to one
the
of the components
and
it
is
not
connected.
Outlet
valve
not
working.
does
Lack of water in
the system or the
inlet valve filter is
blocked.
Outlet
valve
not
working.
A new component
has been
connected to the
product.
Problems with the
probe.
Solution
1. Check connection wiring and
power supply.
2. Run the start-up sequence.
1. Check connection wiring and
power supply.
2. Run the start-up sequence.
1. Check that the outlet path is clear.
2. Check that the steam pipe is not
obstructed, bent or is not siphoning.
3. Clean the outlet valve.
1. Check that the water tap is turned
on.
2. Check that there is water in the
system.
3. Check that the filter at the entrance
to the inlet valve is not blocked.
1. Check that the outlet path is clear.
2. Check that the steam pipe is not
obstructed, bent or is not siphoning.
3. Clean the outlet valve.
1. Check connection wiring and
power supply.
2. Run the start-up sequence.
1. Check the probe connection.
2. Check for any breakage or short-
circuit in the probe.
3. Replace the probe.