7 - e
veryDAy mAintenAnce
Your Transtherm cabinet is a tried and tested appliance.
Maintenance operations to be carried out approximately once a year
•
Unplug and unload the appliance.
•
Clean the water drain at the bottom of the wine cabinet. Pay attention that nothing is blocking this drain.
•
Regularly vacuum the condenser at the back of the appliance.
•
Clean the inside of the compartments with water and a gentle cleaning product.
•
Rinse thoroughly and dry it with a soft rag.
•
Check that the seals are in good condition. It is often necessary to clean the door seal. Using unsuitable cleaning products can cause premature ageing of
the seals. Certain rules must therefore be followed: whenever you clean the seal, always rinse off any cleaning product with clear water. All traces of cleaning
product must be removed from the seal. Transtherm only recommends using a mild soapy solution. If this proves insufficient, it is possible to occasionally
use an ethanol-based solution, provided that the concentration used is less than 10% and that the seal is then rinsed thoroughly with clear water.
8 - o
perAting FAults
Possible incidents
Causes
The temperature
The
pictogram is displaying
has not returned to
within the ±4°C / 39°F
threshold
Operating fault
The
pictogram is still displaying
even though I have taken the corrective
actions above
Open door alarm
The
pictogram is displaying
The level of relative
The
pictogram is flashing
humidity has been <
50 % for over 72 hrs
Temperature sensor
The
pictogram is displaying
fault alarm
Minimum duration of guarantee offered by the manufacturer: 2 years parts.
If your appliance does not seem to be working correctly,
contact your Transtherm retailer.
Minimum duration of guarantee offered by the manufacturer: 2 years parts.
14
GB
Corrective actions
Check that the door is correctly closed.
Check the condition of the door seal.
If you placed a large amount of bottles in your cabinet in the last few hours,
wait a while then check again. If the alarm is still displaying, contact your
Transtherm retailer.
Unplug the cabinet and contact your Transtherm retailer.
Make sure that the door is correctly closed.
• Pour a glass of water into the duct of the tray (see chapter 7, § IV).
• In order to know how often to add water, count the number of days
separating the 1st day you added water and the day when the pictogram was
displayed
After a few hours, the pictogram will disappear.
Contact your Transtherm retailer.
9 - e
nergy AnD technicAl FeAtures
Prestige
Reference
Height
1
mm
1 température
Loft Vintage Glass door
LOXXPV3
960
Loft Vintage Full Glass door
LOXXPV3
960
Manoir porte Glass door
MA1TMV3
1479
Manoir porte Full Glass door
MA1TMV3
1479
Manoir porte solid door
MA1TMV3
1479
Ermitage porte glass door
ER1TGV3
1825
Ermitage porte Full Glass door
ER1TGV3
1825
Ermitage porte solid door
ER1TGV3
1825
3-temperatures
Castel porte glass door
CA3TGV3
1825
Castel porte Full Glass door
CA3TGV3
1825
Castel porte solid door
CA3TGV3
1825
Multi-temperatures
Réserve porte glass door
REMTGV3
1825
Réserve porte Full Glass door
REMTGV3
1825
Réserve porte solid door
REMTGV3
1825
Control accuracy: +/- 1°C (2°F), display accuracy: +/- 1°C (2°F).
1- Height including the top hinges and the feet, adjusted to mid-height.
2- Depth including a gap of 29 mm at the back of the cabinet for ventilation.
According to delegated regulation (EU) 2019/2016 of the European Commission, access energy data about our appliances on the EPREL database by scanning the
QR code visible on your appliance's energy label.
Width
Depth
2
Weight when empty
Recommended temperature range
mm
mm
kg
T° mini (°C / °F) - T° maxi (°C / °F)
680
690
57
0 / 32
680
690
58,5
0 / 32
680
690
78
0 / 32
680
690
80
0 / 32
680
695
63
0 / 32
680
690
88
0 / 32
680
690
90,5
0 / 32
680
695
73
0 / 32
680
690
96
12 / 54
680
690
98,5
12 / 54
680
695
81
12 / 54
680
690
88
12 / 54
680
690
90,5
12 / 54
680
695
73
12 / 54
30 / 86
30 / 86
30 / 86
30 / 86
30 / 86
30 / 86
30 / 86
30 / 86
30 / 86
30 / 86
30 / 86
30 / 86
30 / 86
30 / 86
15
GB