4.3 Intended use
•
VITO is designed for commercial use in the hospitality industry.
•
Observe the safety instructions. Filtration is only possible when the oil is liquid.
•
VITO should only be used by appropriately trained personnel.
•
VITO is only designed for intermittent operation.
No liability will be accepted for improper use!
5. Safety functions
5.1 Tilt and vibration protection
If VITO is placed inclined more than 17°, tilts or vibrates too much due to a defect or incorrect placement, VITO will immediately
stops off the filtration. The power indicator (1) and the filter indicator (2) flash and a repeating acoustic signal sounds.
5.2 Acoustic signal
After the boot-up, a short acoustic signal sounds. VITO is then ready for operation. At the end of each filtration cycle, an acoustic
signal sounds for 5 seconds. The acoustic signal can be deactivated (see chapter 6 Getting started).
5.3 Overtemperature
In case of overheating (control unit >75°C / 167°F), VITO stops the filtration process.
The power indicator (1) flashes and VITO emits an acoustic signal.
Remove VITO from the fryer and store it (see chapter 8 Storage / cooling time).
6. Getting started
6.1 Filtration time
The factory setting of the filtration time is 4 min. 30 sec. Up to 16 filtration cycles are possible directly one after the other.
6.2 Checking the factory settings
1. Press and hold the Start / Stop button (5).
2. Plug in the power cord (10). Meanwhile, hold the Start / Stop button (5).
3. Hold the Start / Stop button (5) for 5 seconds. VITO emits an acoustic signal and filter indicator (2) lights up briefly.
4. Release the Start /Stop button (5).
5. The programmed filtration cycle time is indicated by the flashing of the LEDs.
6. The power indicator (1) shows 1 minute per flash
7. The filter indicator (2) shows 30 seconds per flash
e.g.: 4x red = 4 min.
1x green = 30 sec.
= filtration time: 4 min. 30 sec.
6.3 Offline programming
6.3.1 Adjusting the filtration time
To set the filtration time, follow the steps in chapter 6.2 Checking the factory settings, then:
1. Press Start / Stop button (5) immediately after the filtration time is displayed.
2. Press Start / Stop button (5) to extend the filtration time by 30 seconds (starts at 0 sec.).
(e.g. press 3x for 1 min 30 sec. etc.)
3. When the desired filtration cycle time has been set, wait until the filter indicator (2) lights up briefly and an acoustic signal
sounds.
4. Unplug the power cord (10).
6.3.2 Turning the acoustic signal on/off
To adjust the volume of the signal, follow the instructions in chapter 6.2 Checking the factory settings, then:
1. Wait until the filter indicator (2) lights up briefly and a short acoustic signal sounds
2. Press Start / Stop button (5) to adjust the signal.
3. The LEDs show the status:
Power indicator (1) = Sound off
Power indicator (1) + filter indicator (2) = Sound on
4. When the desired setting has been made, wait until the filter indicator (2) lights up briefly and a acoustic signal is audible.
5. Unplug the power cord (10).