Granizadora Digital Controls And Signals - Solera Eco D-112 Manuel Pour L'emploi Et L'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

When you put the tank back
in its place verify that the
low tension contact wires
are in the guides of the
terminal board. If they are
not, the lamp and the
augers will not work (pic. 25
in appendix-91).
Connect the machine to the
power supply.
Warning!
Any time the covers (lamp)
are removed, for security
reasons, the augers and the
cooling system will stop
working.
Condenser cleaning
procedure
Remove the side panel of the 2
or 3 tanks machine, or the back
panel of the one tank machine
by unscrewing the screws on
the bottom and clean the
radiator with a soft brush or (if
possible) with compressed air.
Outlet restriction
Granizadora Digital has an
accessory called Restriction
(pic. 28 in appendix-91), it is a
shaped piece that is applied on
the ending part of the
transparent tank outlet. It has
the following advantages:
The product, liquid (clod
drink) or semi-liquid (low
density slush), is canalized
directly in the glass;
The restriction is easy to
pull out, therefore, it is
possible to easy wash the
ending part of the outlet
without having to dismantle
the whole transparent tank,
with a consequent decrease
of the machine cleaning
times. In summary, the only
part which is not
refrigerated, where an
accumulation of the
product is more likely to
happen, can be now
removed and washed.
This restriction has some
gaskets (O-ring) that must be
wet with water before inserting
them on the outlet terminal part.
This is to make the introduction
easier and to avoid that O-ring
goes outside their proper
locations.
On the restriction there is the
image of an arrow and of a
glass that, while inserting it,
must face the operator.
Granizadora Digital
controls and signals
- 20 -
Lamp light On / Off Intensity
regulation
The light of the lamp can be
turned on and off by pressing
the
button; if you keep the
button pressed and at the
same time you press the
buttons, it is possible to
increase or decrease the light
intensity; if you keep the
button pressed, the display will
signal the light status. It will turn
off if the pressure of the button
caused the light to be turned off
and it will show a number that
indicates the level of the lamp
light intensity (2 min - 9 max).
Operator security
If you open the tank lifting the
lamp, the augers will stop.
Keyboard, augers and cooling
system block
It is possible to block the
keyboard. You unblock or block
the buttons by lifting the lamp
and pressing the
and
buttons at the same time; the
block status is signaled on the
display through the decimal
point lighting.
For technical reason the
keyboard is unlocked when the
machine is switched off.
Gear electronic stop bypass
As you already know, for
security reasons, when a tank
is open, the augers stop
turning. However, the augers
stop can be also caused by a
malfunctioning of 1 and/or 2
contacts, or by the accidental
or