Start-up
Attention! The pump must never run dry.
Possible consequence: The pump will be destroyed.
Protective measure: Check the water level at regular intervals. Always place the unit below water level.
Attention! Risk of injury due to unexpected start-up.
The temperature monitor switches the unit off automatically in the event of overload. The unit is switched on
again automatically as soon as it has cooled down.
Possible consequences: Risk of injury due to fast rotating components.
Protective measures: Always isolate the unit (switch off and disconnect from the power supply) before
starting any work on the unit.
This is how to connect the power supply:
Switching on: Connect the unit to the mains. The unit switches on as soon as the power connection is established.
Switching off: Disconnect the unit from the mains.
Note:
A brand-new pump will only achieve its maximum capacity after several operating hours.
If there is a blockage in the pump when it is switched on or if it runs dry, a pre-programmed self-test (Environmental
Function Control - EFC) is automatically performed. The pump tries to start up at regular intervals and run through dif-
ferent speeds to overcome the fault (dry run or blockage). The pump switches off after approx. 2 minutes of un-
successful start-up attempts and repeats the self-test after approx. 30 minutes.
Manual transmitter (E 13)
Check the function of the manual transmitter by actuating one of its buttons. The control LED must light up. Up to 80 m
reach, depending on the terrain. Replace the unit battery when the transmitting capacity fades (approx. after one year).
Teaching in the manual transmitter
Actuate the teach-in key (E 12) on the receiver for approx. 1 second. Then actuate top left transmitting key for at least
3 seconds. A maximum of 10 transmitters can be taught in according to this order.
Deleting the transmitter
When the teach-in key (E 12) on the receiver is actuated for at least 5 seconds, the transmitter is reset to its delivery
status. Following this, the manual transmitter can be taught in.
Functions at the manual transmitter
Pump 1 off (0), Pump 1 on (I). Pump 2 off (0), Pump 2 on (I). Invoke memories 0 and I. Reassign memories 0 and I
(factory setting: 0 = 25 % and 1 = 75 %). Activated pumps (+) = larger water quantity, (-) = smaller water quantity.
Battery change
Push the lid beneath the keys down and insert new batteries, type 23A. Ensure correct polarity.