5.
Once all options are configured, the system returns to the base configuration menu.
6.
Repeat the process described above to configure other wireless devices.
[804][801] RF Jam Detect
To configure RF jamming:
1.
Enter Installer Programming section [804][801] then select one of the following options:
00–Disabled
l
01–UL20/20-USA
l
02–EN30/60-Europe
l
03–Class630/60-British
l
2.
Press [*] to accept the selection.
3.
Press [#] to exit the section.
[804][802] Wireless Supervision Window
For EN installations, 1 hour or 2 hours must be selected.
When option 06 is used, which configures the system to generate fault conditions after a device has
been detected as absent for 24 hours, smoke detectors generate a fault condition after a maximum of
18 hours when the 200s supervision toggle option is disabled.
To program the Wireless Supervisory Window:
1.
Enter Installer Programming section [804][802].
2.
Select one of the following options by scrolling or entering the hotkey:
00–Disabled
l
01–After 1Hour
l
02–After 2Hour
l
03–After 4Hour
l
04–After 8Hours
l
05–After 12Hours
l
06–After 24Hours
l
3.
Press [*] to accept the selection.
4.
Press [#] to exit the section.
Note:
For UL Residential Burglary (UL1023), Home Health Care (UL1637), ULC Residential Burg-
lary (ULC/ORD-C1023) installations, the maximum Supervision window shall be set to 24 hours.
For UL Residential Fire (UL985) installations, the maximum supervision window is set to 200s.
For UL Commercial Burglary (UL1610/UL365) and ULC Residential Fire (ULC-S545), the maximum
supervision window shall be set to 4 hours.
[804][810] Wireless Option 1
To program wireless options:
1.
Enter Installer Programming section [804][810].
2.
Select one of the following options by scrolling or entering the hotkey:
01–RF Delinquency
l
02–WirelessSupervisory/RF Jam Alarm
l
03–WirelessTamper
l
04–Fire Supervision
l
3.
Press [*] to accept the selection and [#] to exit.

[804][841] Motion Cameras

To program motion cameras:
1.
Enter Installer Programming section [804][841].
2.
Select one of the following options by scrolling or entering the hotkey:
- 9 -