8.
Light the "IGNITION BURNER" first, push and turn the left Control Knob to HIGH
position.
9.
Immediately press the Electric Igniter for 3-4 seconds to light the Burner.
10. If ignition does not occur in 5 seconds, turn the "IGNITION BURNER" Control Knob
and gas source OFF and conduct a leak test of ALL gas connections and gas sources
as explained in the Use and Care section of this manual. If no leaks are detected, wait
5 minutes for any gas to clear and repeat the lighting procedure.
11. After IGNITION BURNER is lit, turn the tank valve SLOWLY one more 1/4 of a turn for
1/2 of one complete turn.
12. Once the IGNITION BURNER is lit, you light all the burners 3,2,1,5 and 6 in that order
by turning its Control Knob to HIGH.
LIGHTING USING MATCH LIGHT EXTENSION ROD
1.
Turn OFF all burner valves.
2.
Make sure the lid is open.
3.
Place a lighted match between the
coils on the Match Holder and
hold next to the burner.
4.
Turn the control knob(s) to the
"HIGH" position. Burner should
light immediately.
5.
If the burner does not light in 5
seconds turn the knob off, wait 5
minutes and repeat above
procedures.
GR2045401-MF-00 / GR2045402-MF-00
20
20121205