EXTERNAL AIR CONNECTION, AIRSYSTEM
All RAIS/ATTIKA wood-burning stoves can be supplied with
external air. We call this external air supply AirSystem. The air
intake to the system can be concealed by installing it in either
the floor or the wall behind the stove.
AIR CONNECTION THROUGH THE FLOOR
Q-TEE 57
1. R emove the reflector plate (1) by removing the 4 screws (2).
2. T ap out the knockout blank in the reflector plate using a
hammer.
3. R emove the two screws in the damper and one in the
bottom of the combustion chamber (3).
4. R eplace the three screws with spacers (4) and use these
screws (3) to mount the air box on these spacers.
5. R eattach the reflector plate (1).