Télécharger Imprimer la page

Trumpf TruConvert AC 3025 Manuel Opérateur page 121

Masquer les pouces Voir aussi pour TruConvert AC 3025:

Publicité

Number
Message
50003
Overtemperature
balancer.
50004
Ambient tempera-
ture over allowed
range.
50005
Overcurrent L1.
50006
Overcurrent L2.
50007
Overcurrent L3.
50008
Overcurrent balan-
cer.
50009
Overvoltage grid L1.
50010
Overvoltage grid L2.
50011
Overvoltage grid L3.
50012
Overvoltage filter
capacitor L1.
50013
Overvoltage filter
capacitor L2.
50014
Overvoltage filter
capacitor L3.
50015
Overvoltage DC link
positive part.
50016
Overvoltage DC link
negative part.
50018
Overcurrent L1
hardware.
A67-0141-00.BKfr-0
01-09
Effect
No operation pos-
sible.
No operation pos-
sible.
Device switches off.
Device switches off.
Device switches off.
Device switches off.
No operation pos-
sible.
No operation pos-
sible.
No operation pos-
sible.
Device switches off.
Device switches off.
Device switches off.
Device switches off.
Device switches off.
Device switches off.
2022-03-23
Cause
Action
Overtemperature
Check the fan and
balancer bridge.
the ambient tempe-
rature.
Ambient tempera-
Check the ambient
ture over allowed
temperature.
range.
Overcurrent L1.
Check cabling of
L1, grid voltage
sense lines, AC
contactor, external
components (fuses
etc.)
Overcurrent L2.
Check cabling of
L2, grid voltage
sense lines and AC
contactor, external
components (fuses
etc.)
Overcurrent L3.
Check cabling of
L3, grid voltage
sense lines and AC
contactor, external
components (fuses
etc.)
Overcurrent balan-
Contact service.
cer bridge.
Overvoltage grid L1.
Check grid voltage
L1 and external
devices.
Overvoltage grid L2.
Check grid voltage
L2 and external
devices.
Overvoltage grid L3.
Check grid voltage
L3 and external
devices.
Overvoltage filter
Check grid voltage
capacitor L1.
L1, grid voltage
sense lines and AC
contactor.
Overvoltage filter
Check grid voltage
capacitor L2.
L2, grid voltage
sense lines and AC
contactor.
Overvoltage filter
Check grid voltage
capacitor L3.
L3, grid voltage
sense lines and AC
contactor.
Overvoltage DC link
Check DC link vol-
positive part.
tage and midpoint.
Overvoltage DC link
Check DC link vol-
negative part.
tage and midpoint.
Overcurrent L1.
Check cabling of
L1, grid voltage
sense lines and AC
contactor.
Recherche des erreurs
Detec-
ted by
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
115

Publicité

loading