AUGER AND AUGER MOTOR
The 2 RPM auger motor turns the auger lifting pellets up the auger tube.
The pellets ed down a tube and into the firepot. The auger is controlled by the control board.
OVER TEMPERATURE THERMOSTAT
This safety switch is installed on the bottom of hopper and will shut off the heater if it senses
excessive temperatures (70 degrees).
CONVECTION BLOWER THERMOSTAT
This switch is installed on the vent pipe and turns the convection blower on when the heater is
above 40 degrees.
EN
The heater is mainly made up of following items:
1. Combustion burn pot
2. Exhaust fan
3. Room circulation fan and auger motor.
The following is a list of main components and their
functions:
IGNITER
The HEATER comes equipped with an automatic electric
igniter for lighting the fuel when the heater is in lighting
mode only.
The igniter remains energized for the first eight minutes of
the lighting sequence.
VACCUM SWITCH
The HEATER has a safety vacuum switch located behind
the left door, fastened to the base.
If a low pressure is created in the firebox by a leak,
opening the front door, a blocked flue, or unsealed ash
drawer, the vacuum switch will sense it and cause the
heater to go into a shutdown mode.
8
Version: 10